Twisting loop technique for anterior mitral cords shortening and evolution

نویسندگان

  • I Moriones
  • JL Fernandez
  • R Sanchez
  • L Jimenez
  • R Sadaba
  • F Gomez
چکیده

Background It is a known fact that the surgery of the anterior leaflet presents more difficulties and more dubious results than in the posterior leaflet. The use of artificial chordae is not always effective and measure its length is a challenge for the surgeon. So we present our long-term results with our new original technique for shortening the elongated chordae we call, “twisting loop technique” (TLT).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Repair of Mitral Valve Using Triangular Resection of Anterior Leaflet & Annuloplasty Ring

Various surgical techniques have been described for the repair of mitral valve with or without using an annuloplasty ring depending upon the pathological changes. Isolated prolapse of the anterior mitral leaflet with severe mitral regurgitation is relatively uncommon compared to prolapse of the posterior mitral leaflet. The technique commonly used is edge-to-edge repair, Chordal transfer and sh...

متن کامل

Feasibility of mitral valve repair using the loop technique.

PURPOSE The most difficult aspect of chordal replacement in a mitral valve repair using expanded polytetrafluoroethylene (ePTFE) sutures, is determining the appropriate length of artificial chorda and ligation of the ePTFE sutures without the knot sliding. PATIENTS AND METHODS We adopted a loop technique reported by Mohr et al. in 12 consecutive cases from October 2005. Nine cases were compar...

متن کامل

Use of expanded polytetrafluoroethylene sutures as artificial tendinous cords in children with congenital mitral regurgitation.

OBJECTIVE To determine the efficacy in the intermediate term of artificial cords inserted in children with congenital mitral regurgitation. METHODS We reconstructed the tendinous cords using expanded polytetrafluoroethylene (ePTFE) sutures in 11 children with severe mitral regurgitation. In these patients, the aortic (anterior) leaflet of the mitral valve had been markedly prolapsed, the tend...

متن کامل

Comparing outcomes of reconstruction of anterior cruciate ligament rupture with fixed loop and adjustable loop

Background: Recently, the surgical methods are used in patients with anterior cruciate ligament rupture and have been associated with successful results. There are different results in the term of using of the surgical methods for anterior cruciate ligament that often is associated with some complications such as infection, static laxity, remaining the pain, need to recurrence surgery, and limi...

متن کامل

Active Vibration Suppression of a Nonlinear Flexible Spacecraft

In this article, the issue of attitude control and active vibration suppression of a nonlinear flexible spacecraft is assessed through piezoelectric patches as actuator and sensors. Two controller loops are applied: the inner loop, to make the panel vibration damped through piezoelectric patches; and the outer loop, to perform spacecraft maneuver using the reaction wheel acting on the hub. An o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013