Coherence-Gated Sensorless Adaptive Optics Multiphoton Retinal Imaging
نویسندگان
چکیده
Multiphoton microscopy enables imaging deep into scattering tissues. The efficient generation of non-linear optical effects is related to both the pulse duration (typically on the order of femtoseconds) and the size of the focused spot. Aberrations introduced by refractive index inhomogeneity in the sample distort the wavefront and enlarge the focal spot, which reduces the multiphoton signal. Traditional approaches to adaptive optics wavefront correction are not effective in thick or multi-layered scattering media. In this report, we present sensorless adaptive optics (SAO) using low-coherence interferometric detection of the excitation light for depth-resolved aberration correction of two-photon excited fluorescence (TPEF) in biological tissue. We demonstrate coherence-gated SAO TPEF using a transmissive multi-actuator adaptive lens for in vivo imaging in a mouse retina. This configuration has significant potential for reducing the laser power required for adaptive optics multiphoton imaging, and for facilitating integration with existing systems.
منابع مشابه
Adaptive Optics Optical Coherence Tomography for in Vivo Retinal Imaging
Optical coherence tomography (OCT) is a non-invasive micrometer-resolution volumetric imaging modality that has been employed in diverse applications. In this thesis, we first describe a GPU accelerated program to perform FDOCT data processing and real time 3D volumetric rendering. The real time visualization of volumetric images provided by the GPU acceleration was essential to the rest of the...
متن کاملLens-based wavefront sensorless adaptive optics swept source OCT
Optical coherence tomography (OCT) has revolutionized modern ophthalmology, providing depth resolved images of the retinal layers in a system that is suited to a clinical environment. Although the axial resolution of OCT system, which is a function of the light source bandwidth, is sufficient to resolve retinal features at a micrometer scale, the lateral resolution is dependent on the delivery ...
متن کاملWavefront sensorless adaptive optics ophthalmoscopy in the human eye
Wavefront sensor noise and fidelity place a fundamental limit on achievable image quality in current adaptive optics ophthalmoscopes. Additionally, the wavefront sensor 'beacon' can interfere with visual experiments. We demonstrate real-time (25 Hz), wavefront sensorless adaptive optics imaging in the living human eye with image quality rivaling that of wavefront sensor based control in the sam...
متن کاملImaging subcellular scattering contrast by using combined optical coherence and multiphoton microscopy.
The structural origin of scattering contrast from single cells is examined by using a combined optical coherence and multiphoton microscope based on a 12 fs Ti:sapphire source and a 0.95 NA objective. High-resolution coherence-gated scattering images from single cells are coregistered and compared with two-photon-excited fluorescence images. Scattering contrast is observed from mitochondria, pl...
متن کاملOptimization-based wavefront sensorless adaptive optics for multiphoton microscopy.
Optical aberrations have detrimental effects in multiphoton microscopy. These effects can be curtailed by implementing model-based wavefront sensorless adaptive optics, which only requires the addition of a wavefront shaping device, such as a deformable mirror (DM) to an existing microscope. The aberration correction is achieved by maximizing a suitable image quality metric. We implement a mode...
متن کامل