Corrosion of cemented titanium femoral stems.

نویسندگان

  • S R Thomas
  • D Shukla
  • P D Latham
چکیده

Cemented titanium stems in hip arthroplasty are associated with proximal cement-stem ebonding and early failure. This was well publicised with the 3M Capital hip. However, corrosion in this setting has been reported with only one stem design and is less widely accepted. We present a series of 12 cemented titanium Furlong Straight Stems which required revision at a mean of 78 months for thigh pain. At revision the stems were severely corroded in a pattern which was typical of crevice corrosion. Symptoms were eliminated after revision to an all-stainless steel femoral prosthesis of the same design. We discuss the likely causes for the corrosion. The combination of a titanium stem and cement appears to facilitate crevice corrosion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Metal debris concentrations in soft tissues adjacent to loosened femoral stems is higher in uncemented than cemented implants

BACKGROUND There are still many questions related to aseptic femoral stem loosening. Systemic and local immune responses to the implanted "foreign body" is one of the reasons for loosening. The purpose of the study was to measure metal ion concentration (Ti, Co, Cr, Mo, Ni, Al) around loosened femoral stems and compare their levels around uncemented and cemented implants. METHODS This paper r...

متن کامل

Long-term survival of a cemented titanium-aluminium-vanadium alloy straight-stem femoral component.

We present a retrospective series of 170 cemented titanium straight-stem femoral components combined with two types of femoral head: cobalt-chromium (CoCr) alloy (114 heads) and alumina ceramic (50 heads). Of the study group, 55 patients (55 stems) had died and six (six stems) were lost to follow-up. At a mean of 13.1 years (3 to 15.3) 26 stems had been revised for aseptic loosening. The mean f...

متن کامل

Is there still a place for the cemented titanium femoral stem?

BACKGROUND AND PURPOSE Despite the fact that there have been some reports on poor performance, titanium femoral stems intended for cemented fixation are still used at some centers in Europe. In this population-based registry study, we examined the results of the most frequently used cemented titanium stem in Norway. PATIENTS AND METHODS 11,876 cases implanted with the cemented Titan stem were...

متن کامل

Medium-term Outcome of Cemented Titanium Stems

Early failures have seen titanium fall from favour as a material for cemented femoral stems. Between 1989 and 1994, we performed a prospective review of a consecutive series of 122 cemented total hip replacements using the Ultima straight textured titanium stem, and report the fiveto ten-year clinical and radiological outcomes. There were no revisions for loosening of the femoral stem. Revision...

متن کامل

The effect of surface finish and of vertical ribs on the stability of a cemented femoral stem: an in vitro stair climbing test.

The search for improved femoral fixation in cemented total hip arthroplasty is ongoing. Two design variables, surface finish and stem contour, were evaluated. Sixteen titanium femoral stems of one design were cemented into fiberglass femora. One half of the components had a polished surface and the rest had a roughened finish. Within each group, 4 stems had vertically oriented ribs on the proxi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 86 7  شماره 

صفحات  -

تاریخ انتشار 2004