High accuracy dual lens transmittance measurements.
نویسندگان
چکیده
We show how to determine the transmittance of short focal length lenses (f approximately 19 mm and f approximately 2 5 mm, in this case) with a combined uncertainty of 3 parts in 10(4) or better by measuring transmittances of lens pairs of a set of three or more lenses with the same nominal focal length. Uncertainties are minimized by optimizing the radiometric design of the setup and the measurement procedure. The technique is particularly useful in systems where the detector acceptance angle limits the beam geometry to relatively collimated beams.
منابع مشابه
Analysis of reflectance and transmittance measurements on absorbing and scattering small samples using a modified integrating sphere setup.
The aim of the present paper is to analyze reflectance and transmittance measurements on small scattering and absorbing samples. The long term goal is to perform quantitative, spectroscopic in vivo measurements of pigments in small samples of plant material. Small samples such as small leaves constitute a special experimental challenge in cases in which the sample beam has a larger cross-sectio...
متن کاملElectrical μ-Lens Synthesis Using Dual-Junction Single-Photon Avalanche Diode
This work presents a dual-junction, single-photon avalanche diode (SPAD) with electrical μ-lens designed and simulated in 90 nm standard complementary metal oxide semiconductor (CMOS) technology. The evaluated structure can collect the photons impinging beneath the pixel guard ring, as well as the pixel active area. The fill factor of the SPAD increases from 12.5% to 42% in comparison with simi...
متن کاملCharacterization of thin films based on reflectance and transmittance measurements at oblique angles of incidence.
The optical parameters of a SiO2 thin-film coating determined from the spectral reflectance and transmittance measurements at various incidence angles, including the normal incidence and the Brewster's angle, are compared in this paper. The high-accuracy measurements were carried out through visible-near-infrared spectral regions by using our purpose-built instruments. The optical parameters ob...
متن کاملHuman lens transmission of blue light: a comparison of autofluorescence-based and direct spectral transmission determination.
PURPOSE Direct measurement of the transmission of light through the human lens is not possible in vivo unless invasive techniques are used. In the current study, a reliable in vivo estimate of the transmission of blue light through the lens was assessed by comparing an indirect and noninvasive method based on autofluorescence measurements with a direct method. METHODS Total transmission of bl...
متن کاملTesting the radiometric accuracy of Fourier transform infrared transmittance measurements.
We have investigated the ordinate scale accuracy of ambient temperature transmittance measurements made with a Fourier transform infrared (FT-IR) spectrophotometer over the wavelength range of 2-10 mum. Two approaches are used: (1) measurements of Si wafers whose index of refraction are well known from 2 to 5 mum, in which case the FT-IR result is compared with calculated values; (2) comparison...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied optics
دوره 46 22 شماره
صفحات -
تاریخ انتشار 2007