Modified glucose oxidase method for determination of glucose in whole blood.
نویسندگان
چکیده
We have modified an ultramicro method for determining glucose with glucose oxidase-peroxidase-odianisidine. Capillary blood is diluted in isotonic NaF (17.6-17.8 g/liter), the cells are removed, and glucose is determined after a 20-mm incubation with enzyme-containing reagent. Increasing the enzyme concentration fourfold nullifies interference from ascorbic acid and hemolysis, while greatly decreasing interference from bilirubinemia. If necessary, bilirubin is removed completely by coprecipitation with protein. Interference from uric acid is minimized by incorporating it into the standards. Several other suspected interferences proved inconsequential. Isotonic NaF does not inhibit the enzymes used, and preserves glucose in blood for at least 2 h. Avoiding protein precipitation and shortening the incubating time significantly lessens analytical time without affecting precision. Additional Keyphrases: glucose in plasma, serum, cerebrospinal fluid, urine #{149} peroxidase #{149} o-dianisidine #{149} isotonic NaF diluent #{149} pediatric application #{149} predicting wholeblood glucose value from hematocrit, erythrocyte, plasma values
منابع مشابه
A Simple Image Analysis Method for Determination of Glucose by using Glucose Oxidase CdTe/TGA Quantum Dots
Glucose, as the major energy source in cellular metabolism, plays an important role in the natural growth of cells. Herein, a simple, rapid and low-cost method for the glucose determination by utilizing glucose oxidase and CdTe/thioglycolic acid (TGA) quantum dots (QDs) on a thin layer chromatography (TLC) plate has been described. The detection was based on the combination of the glucose enzym...
متن کاملDetermination of Blood Glucose Concentration by Using Wavelet Transform and Neural Networks
Background: Early and non-invasive determination of blood glucose level is of great importance. We aimed to present a new technique to accurately infer the blood glucose concentration in peripheral blood flow using non-invasive optical monitoring system. Methods: The data for the research were obtained from 900 individuals. Of them, 750 people had diabetes mellitus (DM). The system was ...
متن کاملA New Method to Evaluate Fasting Plasma Glucose by Salivary Glucose Measurement
Objective:Fasting plasma glucose (FPG) analysis is the most importantmethod for detection and diagnosis of diabetes mellitus. Due to difficulty and problems of this method for determination of glycemia in diabetic patients, recently the use of Fasting Salivary Glucoseas a simple and non-invasive method to evaluate FPGhas came into significant considerationof specialists. The aim of this study w...
متن کاملReduction of the interferences of biochemicals and hematocrit ratio on the determination of whole blood glucose using multiple screen-printed carbon electrode test strips.
A practical approach to reduce the interferences of biochemicals and hematocrit ratio (Hct%) in the determination of whole blood glucose using multiple screen-printed carbon electrode (SPCE) test strips is described. SPCE test strips with and without glucose oxidase [i.e., GOD(+)-SPCEs and GOD(-)-SPCEs] were used and the chronoamperometric currents of test glucose solutions with various spiked ...
متن کاملKinetic enzymatic method for automated determination of glucose in blood and serum.
Studies are reported on the reaction kinetics of the glucose assay according to Trinder which involves the specific oxidation of glucose by glucose oxidase and the determination of the hydrogen peroxide released by means of phenol and 4-aminophenazone in the presence of peroxidase. The results have been used to develop a general kinetic fixed-time method for the analysis of glucose in whole blo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 19 3 شماره
صفحات -
تاریخ انتشار 1973