An in vivo comparison of a catheter mounted pressure transducer system with conventional balloon catheters.

نویسندگان

  • I M Stell
  • S Tompkins
  • A T Lovell
  • J C Goldstone
  • J Moxham
چکیده

In the assessment of respiratory muscle function balloon catheters have been widely used for pressure measurements. However, this type of investigation is poorly tolerated by acutely ill patients. This study assessed the performance of a possible alternative, a catheter-mounted miniature pressure transducer (CMT). The assessment consisted of a laboratory study of the linearity, frequency response, and stability of gain and baseline of the CMT system, and an in vivo study directly comparing the CMT and balloon catheter systems in seven normal subjects for a range of respiratory manoeuvres. These were: 1) maximal inspiratory and expiratory pressures against a closed airway, 2) twitch transdiaphragmatic pressure elicited by cervical magnetic phrenic nerve stimulation, and 3) tidal breathing, sniffs and coughs in five body positions. The agreement of the two systems was analysed for measurements of 1) absolute pressures, 2) magnitude of changes in pressure, and 3) rate of change of pressure (maximum relaxation rate after sniff manoeuvres). The CMT system was linear, with a high frequency response and stable gain, but showed baseline drift. The two systems agreed well for measurements of change and rate of change of pressure, but less well for measurements of absolute pressure. The CMT system tested is potentially useful for studies of acute changes in respiratory pressures, or studies of respiratory muscle strength, but would be less useful where accurate measurements of absolute pressures are required.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Skin fold technique for central venous catheter fixation; Comparison with conventional method for postopration infections

Background: Central Venous Catheters (CVCs) are used not only as a tool to access to central venous system, but also for hemodynamic monitoring, parenteral nutrition, chemotherapy and hemodialysis. The use of CVCs is associated with some complications notably infections that are troublesome both to patient and physician. We conducted this study to examine catheter fixation with skin fold techni...

متن کامل

Endoscopically guided spectral-domain OCT with double-balloon catheters

Fourier-domain optical coherence tomography (OCT) and balloon-based catheters have furthered the potential of OCT as a real-time surveillance tool for Barrett's esophagus (BE). However, a balloon catheter, which expands the esophagus and centers the catheter, applies direct pressure on the esophagus. This may affect the tissue appearance and the ability to detect dysplasia in BE. To study this ...

متن کامل

Effect of Foley Catheter in Prepration of Cervix for Delivery

Abstract The aim of this study was comparing the efficacy of induction of labor using balloon Foley catheter with conventional Oxytocin infusion method in cases of unfavorable cervix. 60 pregnant women that had an indication for induction of labor with a singleton vertex fetuses, intact membranes, and bishop score lower than 4 interred in this study and allocated in one of two induction method...

متن کامل

Response characteristics of esophageal balloon catheters handmade using latex and nonlatex materials

The measurement of esophageal pressure allows for the calculation of several important and clinically useful parameters of respiratory mechanics. Esophageal pressure is often measured with balloon-tipped catheters. These catheters may be handmade from natural latex condoms and polyethylene tubing. Given the potential of natural latex to cause allergic reaction, it is important to determine whet...

متن کامل

Comparison of microtransducer and fiberoptic catheters for urodynamic studies.

OBJECTIVE To assess the validity and reproducibility of a fiberoptic transducer urodynamic catheter for urethral closure pressure profiles and leak point pressure determination, using a microtransducer catheter as the standard. METHODS Ninety women without significant pelvic organ prolapse underwent urodynamic evaluations with both fiberoptic and microtransducer catheters. Maximal urethral cl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 13 5  شماره 

صفحات  -

تاریخ انتشار 1999