Automated Measurement of Immature Granulocytes: Performance Characteristics and Utility in Routine Clinical Practice

نویسندگان

  • Balamurugan Senthilnayagam
  • Treshul Kumar
  • Jayapriya Sukumaran
  • Jeya M.
  • Ramesh Rao K.
چکیده

The granulocytic "shift to left" reflects marrow response to bacterial infection, and this may be quantified as band count or immature granulocyte count (IGC). The former value, used widely in neonatal sepsis, has been notoriously difficult to measure accurately and precisely. A reproducible, precise, and accurate counting of immature granulocyte counts may be possible with automation. This study of 200 febrile patients aimed at analysing the performance characteristics of automated immature granulocytes (AIGs) in predicting blood culture and their clinical utility. The absolute (IGC) and relative IG count (IG%) had area under curve (AUC) of 0.69 and 0.66. Moreover, the means of IGC and IG% between culture positive and negative groups were statistically significant suggesting that they are potential markers for bacteremia. IGC of 0.03 × 10(3) cu·mm and IG% of 0.5% offered sensitivity of 86.3% and 92.2%, respectively, and may be used for screening for bacteremia. Higher values, IGC > 0.3, and IG% > 3 had specificity greater than 90%, although the values were infrequent. It may not be long before that these automated hemograms are put into regular diagnostic use.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Immature granulocyte measurement using the Sysmex XE-2100. Relationship to infection and sepsis.

We determined the usefulness of immature granulocyte measurement as a predictor of infection or positive blood culture and compared the results with total WBC count and absolute neutrophil count (ANC). Blood samples from 102 infected and 69 noninfected patients were analyzed using the Sysmex XE-2100 automated blood cell counter (Sysmex, Kobe, Japan). The percentage of immature granulocytes was ...

متن کامل

Reference Values for Immature Granulocytes in Healthy Blood Donors Generated on the Sysmex XE-2100 Automated Hematology Analyer

An increase in immature granulocytes (IG) in peripheral blood is of great importance for the diagnosis of hematological malignancies. Furthermore, it may indicate systemic inflammation. IGs are usually quantified by visual microscopy; however, recent studies have evaluated automated IG count on the DIFF channel and IG detection on the IMI channel of the Sysmex XE-2100 automated hematology analy...

متن کامل

Automated enumeration of immature granulocytes.

The performance characteristics of the XE-2100 (Sysmex, Kobe, Japan) automated immature granulocyte (IG) count were studied. The automated IG count was compared with the manual morphology count and with a proposed reference flow cytometric count. The comparison data were analyzed by both least-squares and Passing-Bablok regression analysis. Long-term imprecision using preserved blood quality co...

متن کامل

Performance characteristics of three automated immunoassays for thyroid hormones

Background: Since the introduction of the first radioimmunoassay, several improvements have been made in the design of immunoassays such as method of antibody production, labeling, automation and detection technology. We performed an analytical evaluation of the new electrochemiluminescent immunoassay (ECLIA) for serum TSH, FT4 and T3 in the Elecsys 2010 immunoassay system and compared the resu...

متن کامل

Evaluation of the Diagnostic Performance of theSysmex XT-2000i Automated Hematology Analyzerin the Detection of Immature Granulocyte

Immature Granulocytes (IG) are normally not present in peripheral blood. Their presence is an important indicator of enhanced bone marrow activation. The present study evaluated the diagnostic performance of the Sysmex XT-2000i automated hematology analyzer in the detection of myelocytes and/or metamyelocytes in patients affected by non-haematological disease, in comparison with manual microsco...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2012  شماره 

صفحات  -

تاریخ انتشار 2012