Critical evaluation of the NR-1000F Auto Refractometer.

نویسندگان

  • S Ghose
  • B K Nayak
  • J P Singh
چکیده

The manifest (dry) refractions of 165 eyes of 86 patients, aged 6 to 75 years, were studied on the Nikon Auto Refractometer NR-1000F. The results obtained were compared with the clinical refractive data, and they were analysed for degree of agreement of various refractive components in different types and grades of refractive errors in the separate age groups. On the NR-1000F the spherical and cylindrical components and spherical equivalents skewed towards more minus (or less plus), especially so in emmetropes, low hypermetropes, and low myopes. This error declined with increasing age over 40 years and was also significantly lower in aphakia and mixed astigmatism. Determination of cylinder axis was found to be reliable on the NR-1000F. In spite of the obvious utility of the device its inbuilt automatic fogging system does not seem adequately to neutralise the patient's accommodative efforts, as the fixation target probably induces instrument myopia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An evaluation of the NR-1000F Auto Refractometer in high refractive errors.

The manifest refractions of 37 high myopic and 16 high hypermetropic eyes in a total of 28 patients, aged 5 to 42 years, were determined on the Nikon NR-1000F Auto Refractometer. The data obtained were compared with the final clinical prescriptions for these eyes and analysed for degree of agreement for the spherical equivalents, sphere components, and cylinder powers and axes. The Auto Refract...

متن کامل

A comparison of cycloplegic and manifest refractions on the NR-1000F (an objective Auto Refractometer).

The manifest (dry) and cycloplegic refractions of 50 eyes of 25 patients aged 8 to 28 years were studied on the Nikon Auto Refractometer NR-1000F (AR) and compared with the results of clinical refraction (CR) under homatropine and the final clinical acceptance on postmydriatic testing. Only patients in the younger age groups with low to moderate refractive errors were included in this study; hi...

متن کامل

A comparison of cycloplegic and manifest refractions on the NR - 100 OF ( an objective Auto Refractometer )

The manifest (dry) and cycloplegic refractions of 50 eyes of 25 patients aged 8 to 28 years were studied on the Nikon Auto Refractometer NR-100OF (AR) and compared with the results of clinical refraction (CR) under homatropine and the final clinical acceptance on postmydriatic testing. Only patients in the younger age groups with low to moderate refractive errors were included in this study; hi...

متن کامل

Comparison of Anterior Corneal Curvature Measurements Using a Galilei Dual Scheimpflug Analyzer and Topcon Auto Kerato-Refractometer

Purpose. To compare anterior corneal keratometry (K) measurements taken by a dual Scheimpflug analyzer and an auto kerato-refractometer. Methods. Sixty-four normal eyes underwent keratometric measurements with both devices. The repeatability of the auto kerato-refractometer measurements was assessed by calculating the coefficient of variation (COV). The interdevice agreement was evaluated using...

متن کامل

Evaluation of patient visual comfort and repeatability of refractive values in non-presbyopic healthy eyes.

AIM To evaluate the intra-operator repeatability in healthy subjects using the WAM-5500 auto-kerato/refractometer and the iTrace aberrometer, to compare the refractive values and the subjective refraction obtained with both devices and to determine which of these three spherocylindrical corrections allows the subject to achieve the best visual comfort. METHODS Forty-two non-presbyopic healthy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 70 3  شماره 

صفحات  -

تاریخ انتشار 1986