Effect of solvent type on microtensile bond strength of a total-etch one-bottle adhesive system to moist or dry dentin.

نویسندگان

  • Paula de Carvalho Cardoso
  • Guilherme Carpena Lopes
  • Luiz Clovis Cardoso Vieira
  • Luiz Narciso Baratieri
چکیده

This study evaluated the effect of organic solvent (acetone or ethanol) on the microtensile bond strengths (MTBS) of an adhesive system applied to dry and moist dentin. Sixteen extracted human third molars were ground to expose a flat occlusal dentin surface and acid etched for 20 seconds (20% phosphoric acid gel, Gluma Etch 20 Gel, Heraeus/Kulzer). After rinsing the acid etchant, an ethanol-based one-bottle adhesive system was applied to the mesial half of the occlusal dentin surface. An acetone-based, one-bottle adhesive system was applied to the distal half of the ground dentin surface. The teeth were randomly assigned to groups. In Group 1, the etched dentin was thoroughly air dried and an ethanol-based one-bottle adhesive system was applied (Gluma Comfort Bond, Heraeus/Kulzer) (GCB). In Group 2, the etched dentin was thoroughly air dried and an acetone-based one-bottle adhesive system was applied (Gluma One Bond, Heraeus/Kulzer)(GOB). In Group 3, excess moisture was removed after acid etching, leaving a moist dentin surface and a one-bottle ethanol-based adhesive was applied (Gluma Comfort Bond). In Group 4, excess moisture was removed after acid etching, leaving a moist dentin surface and an acetone-based adhesive was applied (Gluma One Bond). A hybrid resin composite (Venus, Heraeus/Kulzer) was applied to the bonded surface in four 1-mm increments and light cured according to manufacturer's directions. The specimens were then sectioned with a slow-speed diamond saw in two perpendicular directions to obtain sticks with a cross-section of 0.5 +/- 0.05 mm2. The microtensile bond strength (MTBS) test was performed with a Bencor device in an Instron machine at a crosshead speed of 0.5 mm/minute. The data were subjected to a two-way ANOVA and Scheffé Post hoc test (p < 0.05). The experimental MTBS measured for dry dentin were Group 1 = 37.0 +/- 10.6 and Group 2 = 34.7 +/- 9.0 in MPa (mean +/- SD); and on moist dentin, Group 3 = 50.7 +/- 11.0 and Group 4 = 38.5 +/- 10.5 in MPa (mean +/- SD). The ethanol based adhesives resulted in higher MTBS than acetone-based adhesive (p < 0.008) and bonding to moist dentin resulted in higher MTBS (p < 0.001). GCB applied on moist dentin resulted in statistically higher bond strengths than the other groups. The highest MTBS were achieved with the use of an ethanol-based adhesive to moist dentin.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Solvent Type on Microtensile Bond Strength of a Total-etch One-bottle Adhesive System to Moist, Dry Dentin

This study evaluated the effect of organic solvent (acetone or ethanol) on the microtensile bond strengths (MTBS) of an adhesive system applied to dry and moist dentin. Sixteen extracted human third molars were ground to expose a flat occlusal dentin surface and acid etched for 20 seconds (20% phosphoric acid gel, Gluma Etch 20 Gel, Heraeus/Kulzer). After rinsing the acid etchant, an ethanol-ba...

متن کامل

Sodium fluoride addition to a two-step etch-and-rinse adhesive system: effect on dentin microtensile bond strength and durability

Introduction: Studies have suggested that sodium fluoride (NaF) has an inhibitory effect on the activity of endogenous matrix metalloproteinase enzymes. This study assessed the effect of a fluoride-containing adhesive on microtensile bond&nbsp;strength (&micro;TBS) over time. Material & Methods: In this experimental study, 36 extracted &nbsp;third molars were used to evaluate the &micro;TBS of...

متن کامل

Strength and Durability of a New Adhesive Bond to Superficial Dentin Using Etch and Rinse and Self-Etch Systems: An In Vitro Study

Background and Aim: Data regarding the efficacy of universal adhesives are limited. This study aimed to assess the durability of a universal adhesive bond to superficial dentin using etch and rinse and self-etch modes. Materials and Methods: In this in vitro, experimental study, 32 sound molars were randomly divided into two groups of Scotchbond Universal adhesive with two-step etch and rins...

متن کامل

Comparative study of the microtensile bond strength of three different total etch adhesives with different solvents to wet and dry dentin (in vitro test).

The aim of this study was to compare the microtensile bond strength of three different total etch adhesives: XP Bond (Caulk-Dentsply) versus Excite (Ivoclar/Vivadent) and Prime & Bond NT (Caulk-Dentsply). Forty two (42) third human molars were cut to expose the dentinal surface. They were divided into three groups of 14 teeth (GI: XP Bond, G2: Excite, G3: Prime & Bond NT) and two groups of seve...

متن کامل

بررسی اثر برداشت کلاژن بر میزان استحکام باند برشی چهار سیستم باند عاجی یک جزئی

Background and Aim: Achieving adhesion between restorative materials and dentin as a wet and dynamic surface is an important topic in restorative and especially in conservative dentistry. Adhesion of new dentin bonding systems depends on the formation of hybrid layer and micromechanical retention. Nevertheless, an ideal adhesive system has not yet been introduced .Recent studies reveal an incre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Operative dentistry

دوره 30 3  شماره 

صفحات  -