OBJECTIVE The objective of our study was to investigate tumor conspicuity and the discrimination potential for tumor aggressiveness on diffusion-weighted magnetic resonance imaging (DW-MRI) with high b value at 3-T. MATERIALS AND METHODS The institutional review board approved this study and waived the requirement for informed consent. A total of 50 patients with prostate cancer (69 cancer foci; 48 in the PZ, 20 in the TZ, and one in whole prostate) who underwent multiparametric prostate MRI including DW-MRI (b values: 0, 1000 s/mm2 and 0, 2000 s/mm2) on a 3-T system were included. Lesion conspicuity score (LCS) using visual assessment (1 = invisible for surrounding normal site; 2 = slightly high intensity; 3 = moderately high; and 4 = very high) and tumor-normal signal intensity ratio (TNR) were assessed, and apparent diffusion coefficient (ADC, ×10-3 mm2/s) of the tumor regions and normal regions were measured. RESULTS Mean LCS and TNR at 0, 2000 s/mm2 was significantly higher than those at 0, 1000 s/mm2 (p<0.001 for both). In addition, ADC at both 0, 1000 and 0, 2000 s/mm2 was found to distinguish intermediate or high risk cancer with Gleason score ≥7 from low risk cancer with Gleason score ≤6 (p<0.001 for both). Furthermore, ADC of tumor regions correlated with Gleason score at both 0, 1000 s/mm2 (ρ = -0.602; p<0.001) and 0, 2000 s/mm2 (ρ = -0.645; p<0.001). CONCLUSIONS For tumor conspicuity and characterization of prostate cancer on DW-MRI of 3-T MRI, b = 0, 2000 s/mm2 is more useful than b = 0, 1000 s/mm2.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Signal Intensity of High B-value Diffusion-weighted Imaging for the Detection of Prostate Cancer

Background: Diffusion-weighted imaging (DWI) is a main component of multiparametric MRI for prostate cancer detection. Recently, high b value DWI has gained more attention because of its capability for tumor characterization. Objective: To assess based on histopathological findings of transrectal ultrasound (TRUS)-guided prostate biopsy as a reference, an...

متن کامل

Predicting biochemical recurrence in patients with high-risk prostate cancer using the apparent diffusion coefficient of magnetic resonance imaging

PURPOSE We aimed to investigate whether the apparent diffusion coefficient (ADC) value in diffusion-weighted magnetic resonance imaging predicts the prognoses of patients with high-risk prostate cancer. MATERIALS AND METHODS A total of 157 patients with high-risk prostate cancer (based on D'Amico's criteria) were included in the analysis. Patients underwent preoperative 3.0 Tesla magnetic res...

متن کامل

Quantitative evaluation of computed high B value diffusion-weighted magnetic resonance imaging of the prostate.

OBJECTIVES Computed diffusion-weighted magnetic resonance imaging (cDWI) refers to the synthesizing of arbitrary b value diffusion-weighted images (DWI) from a set of measured b value images by voxelwise fitting. The objectives of this study were to quantitatively analyze the noise and the contrast-to-noise ratio (CNR) in cDWI as a function of b value by numerical simulations and by measurement...

متن کامل

Feasibility of Computed Diffusion Weighted Imaging and Optimization of b-value in Cervical Cancer

PURPOSE To evaluate the feasibility of computed diffusion weighted imaging (DWI) in cervical cancer and investigate the optimal b-value using computed DWI. METHODS The present retrospective study involved 85 patients with cervical cancer in the International Federation of Gynecology and Obstetrics (FIGO) stage IB, IIA or IIB. DWI was obtained with b-values of 0, 100, 500 and 1000 s/mm2. Compu...

متن کامل

Value of 3 Tesla diffusion-weighted magnetic resonance imaging for assessing liver fibrosis

BACKGROUND Limited data are available regarding the role of magnetic resonance imaging (MRI), particularly the new generation 3 Tesla technology, and especially diffusion-weighted imaging (DWI) in predicting liver fibrosis. The aim of our pilot study was to assess the clinical performance of the apparent diffusion coefficient (ADC) of liver parenchyma for the assessment of liver fibrosis in pat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014