Evaluation of the pulsed discharge helium ionization detector for the analysis of hydrogen and methane in breath.

نویسندگان

  • Mark T Roberge
  • John W Finley
  • Henry C Lukaski
  • Anthony J Borgerding
چکیده

Under the appropriate separation conditions the pulsed discharge helium ionization detector (PDHID) was used to detect hydrogen and methane separated from the matrix components of human breath samples. The sensitivity of this method is over an order of magnitude better than published methods using a flame ionization detector (FID) and a thermal conductivity detector (TCD), and has the further advantage of detecting both analytes with only one detector. Limits of detection were 0.3 ppmv for both hydrogen and methane and the method had a linear dynamic range (LDR) of three orders of magnitude (0.3-400 ppm, v/v). The PDHID was also compared to the FID and the TCD in regard to selectivity, sensitivity and reproducibility for high-speed gas chromatography (HSGC). It was shown that the PDHID is as sensitive as the FID for fast separations but is limited by the difficulty of resolving analyte peaks from O2 and N2. The PDHID was at least three orders of magnitude more sensitive than the TCD for all of the analytes examined.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study of laser ablation using nano-second laser pulses

 In this paper, the laser ablation process based on the irradiation of nanosecond pulsed lasers on a copper target surface in the presence of Helium gas is studied. The dynamical behaviors of the generated plasma in the helium gas and evaporated copper at the atmospheric pressure are examined using a laser pulse, laser wavelength of and intensity of 7×1010W/cm2. A one-dimensional thermal model ...

متن کامل

Synergetic Effects of Plasma, Temperature and Diluant on Nonoxidative Conversion of Methane to C2+ Hydrocarbons in a Dielectric Barrier Discharge Reactor

Noncatalytic and nonoxidative conversion of methane in a dielectric barrier discharge (DBD) reactor is examined at different temperatures, gas residence times and input powers. In addition, the ratio of methane to helium as a diluant, is changed in the range of 0.6 to 1.8. Results show significant synergetic effects of plasma, temperature and helium on the methane conversion and C2+</s...

متن کامل

DETECTION AND MEASUREMENT OF ACETONE IN THE BREATH OF DIABETICS BY ION MOBILITY SPECTROMETRY METHOD

Background: The ion mobility spectrometry (IMS) is an analytical technique that is widely used due to its high sensitivity and speed for the detection of ionized molecules in gas phase and under atmospheric pressure. Breath analysis is a new method for obtaining information about person's clinical conditions that is considered by researchers. Human exhaled air contains a variety of components s...

متن کامل

Analyzing and Comparing Energy and Exergy of POXR and SMR Reactors for Producing Hydrogen from Methane Gas

The POXR and SMR methods adopted in producing hydrogen from methane gas are simulated and exergy analysis of both the processes are run for comparison. The effective parameters of the feeding materials ratio and the system temperature for maximizing hydrogen production and increasing efficiency are assessed here. Influenced by the changes in these parameters the unit efficiency is increased up ...

متن کامل

Species and temperature measurements of methane oxidation in a nanosecond repetitively pulsed discharge.

Speciation and temperature measurements of methane oxidation during a nanosecond repetitively pulsed discharge in a low-temperature flow reactor have been performed. Measurements of temperature and formaldehyde during a burst of pulses were made on a time-dependent basis using tunable diode laser absorption spectroscopy, and measurements of all other major stable species were made downstream of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatography. A

دوره 1027 1-2  شماره 

صفحات  -

تاریخ انتشار 2004