Commissioning and quality assurance for intensity‐modulated radiotherapy with dynamic multileaf collimator: Experience of the Pontificia Universidad Católica de Chile

نویسندگان

  • Carlos Daniel Venencia
  • Pelayo Besa
چکیده

The objective of this paper is to present our experience in the commissioning and quality assurance (QA) for intensity modulated radiotherapy (IMRT) using dynamic multileaf collimator (dMLC), sliding window technique. Using Varian equipment solution, the connectivity and operation between all IMRT chain components was checked. Then the following test were done: stability of leaf positioning and leaf speed, sensitivity to treatment interruptions (acceleration and deceleration), evaluation of standard field patterns, stability of dMLC output, segmental dose accuracy check, average leaf transmission, dosimetric leaf separation, effects of lateral disequilibrium between adjacent leaves in dose profiles and multiple carriage field verification. Standard patterns were generated for verification: uniform field, pyramid, hole, wedge, peaks and chair. Weekly QA Protocol include: sweeping gap output, Garden Fence Test (narrow bands, 2 mm wide, of exposure spaced at 2-cm intervals) and segmental dose accuracy check. Monthly QA include: sweeping gap output at multiple gantry and collimator angle, sweeping gap output off-axis, Picket Fence Test (eight consecutive movements of a 5-cm wide rectangular field spaced at 5-cm intervals), stability of leaf speed and leaf motor current test (PWM test). Patient QA procedure consists of an absolute dose measurement for all treatments fields in the treatment condition, analysis of actual leaf position versus planned leaf position (dynalog files) for each treatment field, film relative dose determination for each field, film relative dose determination for the plan (all treatment fields) in two axial planes and patient positioning verification with orthogonal films. The tests performed showed acceptable result. After more than one year of IMRT treatment the routine QA machine checks confirm the precision and stability of the IMRT system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preliminary Evaluation of Productivity and Fruit Quality for Seven Peach Rootstocks in Chile

Fruit productivity and quality of eight years peach and nectarine cultivars (Rich Lady, Ryan Sun, Ruby Diamond and Venus) grafted onto Cadaman-Avimag, Viking, Atlas, GxN 15, GF 677, MRS 2/5 and Nemaguard (control) rootstocks were evaluated. A Split Plot experimental design was used, with each rootstock/scion combination as an experimental unit. Total yield, fruit size distribution, number of fr...

متن کامل

Dosimetric and qualitative analysis of kinetic properties of millennium 80 multileaf collimator system for dynamic intensity modulated radiotherapy treatments.

The aim of this paper is to analyze the positional accuracy, kinetic properties of the dynamic multileaf collimator (MLC) and dosimetric evaluation of fractional dose delivery for the intensity modulated radiotherapy (IMRT) for step and shoot and sliding window (dynamic) techniques of Varian multileaf collimator millennium 80. Various quality assurance tests such as accuracy in leaf positioning...

متن کامل

Morbid obesity in a developing country: the Chilean experience.

a Department of Cardiovascular Diseases, Pontificia Universidad Católica de Chile, Santiago, Chile. b Department of Public Health, Pontificia Universidad Católica de Chile, Santiago, Chile. c Department of Digestive Surgery, Pontificia Universidad Católica de Chile, Santiago, Chile. Correspondence to Claudia Bambs (e-mail: [email protected]). doi:10.2471/BLT.07.048785 (Submitted: 18 October 200...

متن کامل

Physical and Dosimetric Aspect of Euromechanics Add-on Multileaf Collimator on Varian Clinac 2100 C/D

Background: Before treatment planning and dose delivery, quality assurance of multi-leaf collimator (MLC) has an important role in intensity-modulated radiation therapy (IMRT) due to the creation of multiple segments from optimization process.Objective: The purpose of this study is to assess the quality control of MLC leaves using EBT3 Gafchromic films.Material and Methods: Leaf Position accur...

متن کامل

Foundations of Modern Graph Query Languages

RENZO ANGLES, Universidad de Talca & Center for Semantic Web Research MARCELO ARENAS, Pontificia Universidad Católica de Chile & Center for Semantic Web Research PABLO BARCELÓ, DCC, Universidad de Chile & Center for Semantic Web Research AIDAN HOGAN, DCC, Universidad de Chile & Center for Semantic Web Research JUAN REUTTER, Pontificia Universidad Católica de Chile & Center for Semantic Web Rese...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2004