Power Frequency Magnetic Field Survey in Indoor Power Distribution Substation in Egypt
نویسندگان
چکیده
In our modern society electricity is vital to our health, safety, comfort and well-being. While our daily use of electricity is often taken for granted, public concern has arisen about potential adverse health effects from electric and magnetic – electromagnetic – fields (EMFs) produced by our use of electricity. This paper aims to compare between the measured magnetic field values and the simulated models for the indoor medium to low voltage (MV/LV) distribution substations. To calculate the magnetic flux density in the substations, interactive software SUBCALC is used which is based on closed form solution of the Biot-Savart law with 3D conductor model. The comparison between the measured values and the simulated models was acceptable. However there were some discrepancies, as expected, may be due to the current variation during measurements. Keywords—Distribution substation, magnetic field, measurement, simulation.
منابع مشابه
Power-frequency magnetic field calculation around an indoor transformer substation
The authors propose a full three-dimensional (3D) calculation model based on a multipole technique able to predict the magnetic field pollution outside of indoor medium voltage/low voltage (MV/LV) transformer substations. The authors demonstrate that the proposed model may be advantageously used in all problems related to the characterization of the electromagnetic environment around a MV/LV tr...
متن کاملMeasurement of the Magnetic Fields from High-Voltage (230 kV) Substations in Tehran and Assessment of Their Effects
Introduction: Recent industrial developments in human societies have caused rapid advancements in technologies of production and distribution of electricity, which in turn result in enhancement of power networks and utilization of high voltages. These networks and the high voltages in transfer lines cause the exposure to electric and magnetic fields. In this study, the situation regarding the m...
متن کاملReliability assessment of power distribution systems using disjoint path-set algorithm
Finding the reliability expression of different substation configurations can help design a distribution system with the best overall reliability. This paper presents a computerized a nd implemented algorithm, based on Disjoint Sum of Product (DSOP) algorithm. The algorithm was synthesized and applied for the first time to the determination of reliability expression of a substation to determine...
متن کاملAssessment of Extremely Low Frequency (ELF) Electric and Magnetic Fields in Hamedan High Electrical Power Stations and their Effects on Workers
Introduction: Public and occupational exposure to extremely low frequency (ELF) electric and magnetic fields induced by electrical equipment is a significant issue in the environment and at the workplace due to their potential health effects on public health. The purpose of this study was assessment of the electric and magnetic fields intensities and determination of mental and psychological ef...
متن کاملSensitivity Assessment of Lightning Protection Device Aging Effect on Distribution Substation Insulation
Insufficient electrical endurance of equipment and insulation failure against overvoltage is one of the most effective reasons for failure the power line. Lightening, switching or other disruptive parameters can cause line outage or distribution substation failure. There are different devices used to improve the safety, reliability, and power quality of the system. Surge arresters are one of t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2012