Radiation to Patients during Dynamic Hip Screw Surgery

نویسندگان

  • Zaka Ullah Khan
  • Javaid Iqbal
  • Selvaraj Aravindan
چکیده

Objective: The aim of this study was two fold. To determine the diagnostic reference level (D.R.L.) dose of radiation during dynamic hip screw (D.H.S.) fixation and, to audit the orthopaedic department against this standard. Methods and Materials: A retrospective analysis of 112 consecutive patients between 31st December 2002 and the 6th July 2003, at Darenth Valley Hospital, Dartford, under going dynamic hip screw fixation for proximal femur fractures was carried out. The data was collected from the Radiographers log. The screening time and Dose Area Product (DAP) for each event was analyzed in conjunction with the Radiation Protection Department at Kings College, London. Taking the 75th percentile from the existing data, the DAP was set at 1.05cGy/cm2. The screening time for the procedure was set at 64.2 seconds. An audit to access the performance of the orthopaedic department against these standards was carried out. All grades of surgeons performing this procedure were included in the audit. Results: In the total of 112 patients, there were 32 males and 80 females. The age range was from 27 to 99 years with a mean of 83.96 years. Sixty fractures were on the right side and 52 on the left. The total screening time for the procedures was 78.25 minutes with an average of 0.877 of a minute (i.e.) 52.62 seconds. The total Dose Area Product (DAP) was 96.42cGy/cm2 with an average of 0.860cGy/cm2. Conclusion: At present there are no DRL for orthopedic procedures locally or nationally in the United Kingdom, despite this being a legal requirement since May 2000. The authors have determined a local DRL for DHS fixation which can be used as a guideline for this procedure. We recommend that DRL be set for other orthopedic procedures done under Fluoroscopic guidance, especially procedure involving younger patient.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Intertrochanteric Fracture Fixation with Dynamic Hip Screw and Bipolar Hemiarthroplasty Techniques

Background: At present, there is no consensus on an appropriate treatment modality for intertrochanteric fractures in the elderly with background diseases. The aim of the present study was to compare treatment outcomes of intertrochanteric fractures reduced with dynamic hip screws (DHS) and bipolar hemiarthroplasty in elderly patients with background medical conditions. Methods: In this randomi...

متن کامل

Type II Intertrochanteric Fractures: Proximal Femoral Nailing (PFN) Versus Dynamic Hip Screw(DHS)

  Background: Intertrochanteric fracture is one of the most common fractures of the hip especially in the elderly with osteoporotic bones, usually due to low-energy trauma like simple falls. Dynamic Hip Screw (DHS) is still considered the gold standard for treating intertrochanteric fractures by many. Not many studies compare the DHS with Proximal femoral nail (PFN), in Type II intertrochanteri...

متن کامل

Comparing Therapeutic Outcomes of Dynamic Hip Screw and Multiple Cannulated Screws as Internal Fixation in Femoral Neck Fractures

Background and purpose: Femoral neck fracture is associated with a high rate of side effects, especially in young people, who are usually affected by severe energy shocks. Results after injury depend on some factors, including displacement, fragility, bleeding rate, proper placement, and stable and strong fixation. The aim of this study was to compare dynamic hip screw (DHS) or multiple cannula...

متن کامل

Dynamic hip screw fixation for inter-trochanteric fractures: determinants of outcomes.

OBJECTIVE To evaluate factors associated with revision of dynamic hip screw implant in patients undergoing the procedure for the fixation of intertrochanteric fractures. METHODS The retrospective study was conducted at the Aga Khan University Hospital, Karachi, and comprised records of patients who had undergone dynamic hip screw fixation surgery between 2008 and 2012. Medical records and dat...

متن کامل

Pertrochanteric femoral fractures treated with a dynamic hip screw or a proximal femoral nail. A randomised study comparing post-operative rehabilitation.

We treated 108 patients with a pertrochanteric femoral fracture using either the dynamic hip screw or the proximal femoral nail in this prospective, randomised series. We compared walking ability before fracture, intra-operative variables and return to their residence. Patients treated with the proximal femoral nail (n = 42) had regained their pre-operative walking ability significantly (p = 0....

متن کامل

Comparing the Intramedullary Nailing Method Versus Dynamic Hip Screw in Treatment of Unstable Intertrochanteric Fractures

INTRODUCTION Dynamic Hip Screw fixation is currently considered as a standard treatment for pre-trochanteric fractures; however, due to the long-term hospitalization and some other complications, some researchers have proposed intramedullary nailing as the alternative surgical treatment. The aim of this study was to compare and examine the consequences of the using intramedullary nailing method...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006