Signal-to-noise ratio comparison between surface coils and implanted coils.

نویسندگان

  • L L Arnder
  • M D Shattuck
  • R D Black
چکیده

The signal-to-noise ration (SNR) from implanted coils is widely known to be superior to that from surface coils. This article addresses the quantitative aspects of this improvement by explicitly evaluating the magnetic vector potential in a conducting medium of finite extent for both implanted and surface coils. The predictions of the model are tested with actual image data from spin warp experiments on gelatin phantoms. The authors derived a simplified expression that yields the gain in SNR of an implanted coil relative to that of a surface coil and is valid in many practical situations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)

Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...

متن کامل

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

Comparison between volume and surface coils for pig cardiac metabolism studies with hyperpolarized 13C MRS

Introduction Cardiac metabolism assessment with hyperpolarized 13C in pig models requires dedicated coils design capable to provide large sensitivity regions. This work presents a comparison between a quadrature birdcage coil and a circular coil both designed for hyperpolarized studies of the heart in large animal models with a clinical 3T scanner. The results are presented as Signal-to-Noise R...

متن کامل

Comparison of MR imaging breast coils.

In one volunteer, five breast coils were evaluated for signal-to-noise ratio (SNR), uniformity, comfort, subject orientation, access to the breast, and unilateral imaging options. The four-coil arrays provided superior SNR, imaging flexibility, and access. Uniformity and comfort were issues with all coils. Substantial design differences exist between coils; purchasers should ensure that their s...

متن کامل

An implanted 8-channel array coil for high-resolution macaque MRI at 3 T

An 8-channel receive coil array was constructed and implanted adjacent to the skull in a male rhesus monkey in order to improve the sensitivity of (functional) brain imaging. The permanent implant was part of an acrylic headpost assembly and only the coil element loop wires were implanted. The tuning, matching, and preamplifier circuitry was connected via a removable external assembly. Signal-t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 35 5  شماره 

صفحات  -

تاریخ انتشار 1996