Pre-mixing serum samples with assay buffer is a prerequisite for reproducible anti-Mullerian hormone measurement using the Beckman Coulter Gen II assay.
نویسندگان
چکیده
STUDY QUESTION Does pre-mixing stored serum samples with assay buffer improve the reproducibility of the Beckman Gen II assay for anti-Müllerian hormone (AMH)? SUMMARY ANSWER Pre-mixing serum samples with assay buffer is a prerequisite for reproducible measurement of AMH in serum using the Beckman Coulter Gen II assay. WHAT IS KNOWN ALREADY Discrepancies in the results obtained from AMH assays have raised doubts concerning the clinical utility of measuring AMH. Sample storage conditions may be responsible for the lack of reproducibility of results obtained from the Gen II kit. STUDY DESIGN, SIZE, DURATION This was a prospective study in which serum samples were stored at three different temperatures and assayed for AMH at times 0, 4, 8, 12, 24, 48 h and 1 or 2 weeks after collection. Volunteers (n = 28) were healthy non-pregnant and early pregnant women aged 22-41 years. Anonymized long-term stored samples (n = 42, stored at -20° for 2 weeks) from fertility clinic attendees were also included. For determining the reference range, 179 samples from healthy pregnant women presenting for first trimester screening were used. PARTICIPANTS/MATERIALS, SETTING, METHODS Thirty separate assays were performed by two operators using four different Gen II kit lots with both kit and in-house quality controls (QCs) included in each assay. In addition to the standard protocol, a modified protocol (pre-mixing samples with assay buffer) was used for selected sample groups. MAIN RESULTS AND THE ROLE OF CHANCE In non-pregnant women, AMH concentrations remained unchanged in serum stored for up to 8 h at room temperature, -20 and -80°C. At room temperature, levels started to rise by 24 h, increasing by up to 29% of the time 0 h value by 48 h and 26% after 1 week. Significant changes versus baseline (time 0 h) in measured AMH concentration were also observed after storage at -20 and -80°C (only at the 12 h time point). In the pregnant group, there was a 50% increase above baseline in samples stored for 48 h at room temperature. When samples were pre-mixed with assay buffer, AMH concentrations showed a consistent increase versus the standard assay in both non-pregnant (29%) and pregnant (280%) groups, regardless of storage conditions and duration, but concentrations remained constant during long-term storage (2 weeks). Stored fertility clinic patient samples also exhibited stability of AMH values after a consistent 2-fold increase following pre-mixing. Kit QCs were consistent over 30 weeks using either standard or modified protocols while the in-house pooled serum QC rose over time unless using the modified protocol. Overall, there was a 2-fold increase in medians in the pre-mixed reference range, with the biggest increase observed in the oldest age bracket (41-45 years, 3.4-fold). LIMITATIONS, REASONS FOR CAUTION The cause of the observed instability of AMH in stored serum samples requires further investigation, which is outside the scope of this publication. A larger and wider population study is necessary for a more reliable and clinically relevant reference range. WIDER IMPLICATIONS OF THE FINDINGS Our study has confirmed previous findings of lack of consistency in AMH concentrations when measured with the Gen II assay. Pre-mixing serum samples with assay buffer gave higher but also the most consistent results regardless of storage conditions; therefore, we propose that all serum samples for AMH assay should be pre-mixed with assay buffer. Furthermore, clinical laboratories that offer AMH measurement as part of the assessment of endocrinopathies, such as polycystic ovary syndrome or premature ovarian failure, or for management of ovulation induction as part of assisted reproduction, must re-establish their own normal ranges using the modified method. STUDY FUNDING/COMPETING INTEREST(S) No funding was obtained for this study. There are no conflicts of interest to declare.
منابع مشابه
Anti-Mullerian-Hormone during pregnancy and peripartum using the new Beckman Coulter AMH Gen II Assay
BACKGROUND AMH levels determined by the conventional AMH assay declined during pregnancy and postpartum. A new Beckman Coulter AMH Gen II assay removes the potentially assay-interfering complement which is activated in pregnancy. The aim of this study was to evaluate if the decline of AMH levels in the serum of pregnant women during the course of pregnancy and peripartum was assay-dependent and...
متن کاملWithin-laboratory and between-laboratory variability in the measurement of anti-müllerian hormone determined within an external quality assurance scheme.
Ten laboratories in an external quality assurance scheme used the same assay to measure anti-müllerian hormone concentration (Beckman Coulter Gen II) and received twenty serum samples distributed over a 15 month period. The mean bias for all results was only -0.089%, but there was large coefficient of repeatability of 38.8% (sample bias ranged from -37.9% to +54.7%). While each laboratory showe...
متن کاملBungumL, FranssohnF, BungumM,Humaidan P,GivercmanA.The circadian variation in anti-Müllerian hormone in patients with polycystic ovary syndrome differs significantly from normally ovulating
variation in anti-Müllerian hormone in patients with polycystic ovary syndrome differs significantly from normally ovulating women. PLoS One 2013;9:e68223. Dolleman M, Faddy MJ, van Disseldorp J, van der Schouw TY, Messow CM, Leader B, Peeters PH, McConnachie A, Nelson SM, Broekmans FJ. The relationship between anti-Müllerian hormone in women receiving fertility assessments and age at menopause...
متن کاملAnti-Mullerian hormone: poor assay reproducibility in a large cohort of subjects suggests sample instability.
STUDY QUESTION What is the variability of anti-Müllerian hormone (AMH) concentration in repeat samples from the same individual when using the Gen II assay and how do values compare to Gen I [Diagnostic Systems Ltd (DSL)] assay results? SUMMARY ANSWER The Gen II AMH assay displayed appreciable variability, which can be explained by sample instability. WHAT IS KNOWN ALREADY AMH is the primar...
متن کاملAssessment of the Access AMH assay as an automated, high-performance replacement for the AMH Generation II manual ELISA.
BACKGROUND The manual Generation II (Gen II) ELISA method used to measure Anti-Müllerian Hormone (AMH) from Beckman Coulter has recently been superseded by a fully automated AMH immunoassay. The aim of this study was to evaluate the performance of the Access AMH assay and directly compare it to the modified Gen II ELISA method. A secondary aim was to verify that the fertile age-related AMH rang...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Human reproduction
دوره 29 5 شماره
صفحات -
تاریخ انتشار 2014