Posterior Dislocation of the Hinge-Post Extension in a Rotating Hinge Total Knee Prosthesis

نویسندگان

  • Givenchy Manzano
  • Ran Schwarzkopf
چکیده

The rotating hinge knee prosthesis is a popular intervention in patients lacking stability with highly constrained total knee arthroplasty. Despite improvements in design, nonmechanical and mechanical complications continue to be a problem. Dislocation of the hinge has been widely described, mainly due to the component fracture. Few reports describe isolated dislocation of the rotating stem. We report a case of isolated disengagement of the rotating hinge mechanism, due to severe flexion gap imbalance, leading to subsequent posterior dislocation of the hinge and anterior knee dislocation, in a patient with a history of multiple total knee arthroplasty revisions. This case suggests the importance of the soft tissue balancing, the adequate patellar tracking, and use of a long cylindrical, minimally tapered rotating stem in hinge arthroplasty to minimize hinge dislocation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Total Knee Arthroplasty in Severe Unstable Knee: Case-Report and Literature Review

  Multiplanar or global laxity in arthritic knee is rare , most of this patients have neuromuscular disorder (post poliomyelitis , spinal dystrophy) or history of knee trauma. Ligament insufficiency and severe bone loss is significant in this patient. The estimated prevalence for the concurrence of charcot marie-tooth (CMT) with myasthenia gravis (MG) suggests an extremely rare event. We have p...

متن کامل

Medium-term results with a primary cemented rotating-hinge total knee replacement. A 7- to 15-year follow-up.

We reviewed 100 cemented Endo-model rotating-hinge (Waldemar Link GMBH & Co, Hamburg, Germany) total knee replacements in 80 patients with a mean age of 70 years (56 to 85) at a mean post-operative follow-up of 11 years (7 to 15). Good or excellent results were seen in 91% of knees and survival at 15 years was 96.1%. There were two deep infections, one dislocation and one supracondylar fracture...

متن کامل

Rotating-hinge total knee for revision total knee arthroplasty.

Rotating-hinge knee implants are used for revision total knee arthroplasty in patients with severe ligament instability and bone loss. This study evaluated the outcomes of a series of rotating-hinge knees. Thirty-one NexGen Rotating Hinge Knees (Zimmer, Warsaw, Indiana) were implanted in 29 patients (2 bilateral), with an average age of 72.8 years. Indications for surgery were aseptic loosening...

متن کامل

Evaluation of Stability of Rotating Hinge Knee Prostheses: A Biomechanical Study

Purpose. Rotating hinge knee prostheses should provide a stable situation following reconstruction. We performed a biomechanical analysis to establish the association between design of the central rotational stem (peg) and implant's stability, in a theoretical setting. Methods. Six different rotating hinge designs were tested, and three observers performed two different measurements with a cust...

متن کامل

ROTATING HINGE VERSUS CONSTRAINED CONDYLAR KNEE REPLACEMENT: WHICH ONE IS ACTUALLY MORE CONSTRAINED? A FINITE ELEMENT STUDY

This was Presented in 5th International Congress of Iranian Iranian Society of Knee Surgery, Arthroscopy, and Sports Traumatology (ISKAST), 14-17 Feb 2018- Kish, Iran

متن کامل