Left ventricular volume calculations using a multiplanar transoesophageal echoprobe; in vitro validation and comparison with biplane angiography.

نویسندگان

  • W Krebs
  • H G Klues
  • S Steinert
  • M Sivarajan
  • F P Job
  • F A Flachskampf
  • A Franke
  • T Reineke
  • P Hanrath
چکیده

BACKGROUND Biplane angiographic and transthoracic echocardiographic volume calculations have shown to be sufficiently reliable in symmetric hearts; however, they are unreliable in the presence of aneurysmatic distortions. Multiplane transoesophageal echocardiography offers unobstructed cross-sectional views of the heart from one stable transducer position with the potential of imaging irregular cavity forms more accurately. It was the purpose of this in vitro study to compare the precision of multiplanar transoesophageal echocardiography to that of biplane angiography in determining left ventricular volumes, especially in aneurysmatic models. METHODS Seven silicon rubber models of the left ventricle from post-mortem specimens (four with aneurysms) were filled with 30 different volumes (range 153-256 ml, 197 +/- 30 ml). Echocardiographic cross-sections (20 degree rotational steps) were obtained from different transducer positions, utilizing a multiplanar probe with a central rotational axis. Volumes were calculated using the disc-summation method. For comparison the same volumes were determined by standard biplane angiography. The minimum number of echo cross-section necessary to optimize precision was analysed by calculating volumes for each increasing equidistant rotational step. RESULTS Linear correlation between measured volume using a multiplanar transoesophageal echoprobe and true volume was high (r = 0.97) and significantly better than for biplane angiography (r = 0.88; P < 0.001). Measurement bias and imprecision were also significantly lower with multiplanar echocardiography than with biplane angiography (3.9 +/- 7.1% vs 11.1 +/- 15.4%, and 2.0 +/- 3.7% vs 5.9 +/- 8.3%; P < 0.001). Precision of biplane angiographic volume measurements was significantly influenced by the presence of aneurysmatic distortions. Multiplanar echo volumes, however, were not influenced by left ventricular geometry and transducer positions. Nine echo cross-sections provided optimal precision. CONCLUSIONS Three-dimensional echocardiographic volume calculations using a multiplanar transoesophageal echoprobe and the disc-summation method provide precise measurements unaffected by left ventricular geometry and transducer position in an in vitro setting. Standard biplane angiography is significantly less precise.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SERVO METHOD FOR BP DETERMINATION/Aaslid and Brubakk

left ventricle in dogs. Circulation 60: 1104, 1979 14. Eaton LW, Maughan WL, Weiss JL: Accurate volume determination in the isolated ejecting canine heart from a limited number of two-dimensional echocardiographic cross-sections. (abstr) Am J Cardiol 45: 470, 1980 15. Helak J, Reichek N, Pearlman E, Weber K, Pietra G, Kastor JA: Quantitation of human left ventricular mass and volume by cross-se...

متن کامل

Dobutamine stress echocardiography after coronary artery bypass grafting. Transthoracic vs biplane transoesophageal imaging.

Graft failure or progressive native vessel disease can be a serious problem after coronary artery bypass grafting. However, because of poor image quality it may be difficult to evaluate these patients by transthoracic stress echocardiography. The purpose of this study, therefore, was to evaluate the effectiveness of dobutamine stress echocardiography in the detection of myocardial territories w...

متن کامل

Additional value of biplane transoesophageal imaging in assessment of mitral valve prostheses.

OBJECTIVES To determine whether biplane transoesophageal imaging offers advantages in the evaluation of mitral prostheses when compared with standard single transverse plane imaging or the precordial approach in suspected prosthetic dysfunction. DESIGN Prospective mitral valve prosthesis in situ using precordial and biplane transoesophageal ultrasonography. SETTING Tertiary cardiac referral...

متن کامل

Two-dimensional echocardiographic determination of ventricular volumes in the fetal heart. Validation studies in fetal lambs.

The determination of ventricular volumes in the fetal heart from two-dimensional echocardiography (2DE) may give a better estimate of fetal ventricular size than simple diameter measurements, but the accuracy of this method has not been established. In fetal lambs, we tested whether ventricular volume calculations from 2DE using a biplane Simpson's rule algorithm are accurate. Calculations of l...

متن کامل

Comparative accuracy of apical biplane cross-sectional echocardiography and gated equilibrium radionuclide angiography for estimating left ventricular size and performance.

To compare measurements of left ventricular size and performance obtained by apical biplane cross-sectional echocardiography (CSE) and gated equilibrium radionuclide angiography (RNA), we studied 70 patients, all of whom had single-plane and 30 of whom had biplane left ventricular cineangiography. Wideangle, phased-array CSE images were obtained from two orthogonal apical views and left ventric...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal

دوره 17 8  شماره 

صفحات  -

تاریخ انتشار 1996