Inspiratory Flows and Volumes in Subjects with Non-CF Bronchiectasis Using a New Dry Powder Inhaler Device
نویسندگان
چکیده
INTRODUCTION Drug inhalation via a dry-powder inhaler (DPI) is a convenient, time efficient alternative to nebulizers in the treatment of cystic fibrosis (CF) or non-CF bronchiectasis. Efficient drug administration via DPIs depends on the device resistance and adequate (≥45L/min) inspiratory flows and volumes generated by individuals. Drypowder mannitol is delivered using a RS01 breath-actuated device developed by Plastiape, for Pharmaxis. The study aim was to determine in vivo if non-CF bronchiectasis patients' inspiratory flows and volumes are adequate to use the RS01 DPI device. MATERIALS AND METHODOLOGY An open, non-interventional study; enrolled 17 subjects with non-CF bronchiectasis, 18 to 80 years, with baseline FEV1 ≥1.0L and ≥50‰ predicted. Inspiratory flows and volumes were measured when subjects inhaled in a controlled manner through the RS01 device in series with a spirometer. RESULTS The mean inspiratory volume (IV) of non-CF bronchiectasis subjects was 2.08 ± 0.5L and achieved a mean PIF of 78.6 ± 11.2L/min with the inhaler device. CONCLUSION Use of the RS01 DPI device allowed adequate inspiratory flow and volume for dispersion of dry-powder mannitol in non-CF bronchiectasis patients.
منابع مشابه
Inspiratory Flows and Volumes in Subjects with Cystic Fibrosis Using a New Dry Powder Inhaler Device
INTRODUCTION Drug inhalation via a dry-powder inhaler (DPI) is a convenient, time efficient alternative to nebulizers in the treatment of cystic fibrosis (CF). Efficient drug administration via DPIs depends on the device resistance and adequate (≥ 45L/min) inspiratory flows and volumes generated by individuals. Dry-powder mannitol is delivered using a RS01 breath-actuated device developed by Pl...
متن کامل[Measurement of inspiratory flow for the selection of the inhalation treatment device for asthma and COPD].
AIM To assess the proportion of patients with asthma or chronic obstructive pulmonary disease (COPD) with significant bronchoobstruction who do not have inspiratory flows necessary for the adequate use of dry powder inhaler (DPI) devices Diskus and Turbuhaler. PATIENTS AND METHODS multicentre cross-sectional study that included 400 patients with asthma or COPD (with FEV1 < 60%) aged 5-91 year...
متن کاملInspiratory flows through dry powder inhaler in chronic obstructive pulmonary disease: age and gender rather than severity matters
BACKGROUND Dry powder inhalers (DPIs) are inspiratory flow driven and hence flow dependent. Most patients with chronic obstructive pulmonary disease (COPD) are elderly and have poor lung function. The factors affecting their inspiratory flows through inhalers are unclear. OBJECTIVE To study peak inspiratory flows (PIFs) and their determinants through a DPI in COPD patients of varying age and ...
متن کاملMinimal inspiratory flow from dry powder inhalers according to a biphasic model of pressure vs. flow relationship.
Inhalation therapy using the dry powder inhaler (DPI) is now the first choice for obstructive pulmonary diseases. We previously measured relationships between inspiratory pressure (PI) and flow rate of almost all of the DPIs available in Japan, and described an importance of inspiratory efforts. In the present study, we further analyzed the data obtained in the previous study. Although there we...
متن کاملInspiratory flow rates at different levels of resistance in elderly COPD patients.
Dry powder inhalers (DPIs) are increasingly replacing metered dose inhalers in elderly chronic obstructive pulmonary disease (COPD) patients. However, most DPIs are dependent on inspiratory flow, which is compromised by the ageing process itself. Using the in-check dial method, the present study compared peak inspiratory flow (PIF) rates in 26 elderly COPD patients and 14 matched control subjec...
متن کامل