Quantification of stato-kinetic dissociation by semi-automated perimetry

نویسندگان

  • Jan Schiller
  • Jens Paetzold
  • Reinhard Vonthein
  • William M. Hart
  • Anne Kurtenbach
  • Ulrich Schiefer
چکیده

The difference in threshold sensitivities that are found when examining the visual field (VF) with static versus kinetic perimetric methods is called stato-kinetic dissociation (SKD). In this pilot study, we describe a semi-automated procedure for quantifying SKD. Fifteen patients with VF defects were examined with kinetic and static perimetry. SKD values were defined as positive when the static scotoma was larger than the kinetic one. We found significant local variations of SKD along scotoma borders with the individual reaction time as an important criterion when determining kinetic thresholds. There was a verifiable SKD in all patients with locally negative values in eight subjects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Octopus Semi-Automated Kinetic Perimetry and Humphrey Peripheral Static Perimetry in Neuro-Ophthalmic Cases

Aim. To compare semikinetic perimetry (SKP) on Octopus 900 perimetry to a peripheral static programme with Humphrey automated perimetry. Methods. Prospective cross-section study comparing Humphrey full field (FF) 120 two zone programme to a screening protocol for SKP on Octopus perimetry. Results were independently graded for presence/absence of field defect plus type and location of defect. Re...

متن کامل

Semi-quantitative segmental perfusion scoring in myocardial perfusion SPECT: visual vs. automated analysis

Introduction: It is recommended that the physician apply at least a semi-quantitative segmental scoring system in myocardial perfusion SPECT.  We aimed to assess the agreement between automated semi-quantitative analysis using QPS (quantitative Perfusion SPECT) software and visual approach for calculation of summed stress  score (SSS), summed rest score (SRS) and summed difference score (SDS). ...

متن کامل

Automated combined kinetic and static perimetry: an alternative to standard perimetry in patients with neuro-ophthalmic disease and glaucoma.

OBJECTIVES To create a fully automated, combined perimetry program consisting of a static examination and a kinetic examination, and to compare the results of this test with standard static and kinetic visual fields (VFs). METHODS Fifty-six patients (74 eyes) undergoing neuro-ophthalmic or glaucoma evaluation who had standard static or kinetic perimetry examinations underwent the combined per...

متن کامل

Variability in isopter position and fatigue during semi-automated kinetic perimetry.

BACKGROUND Assessment of factors influencing response variability to repeat presentations of III4e stimuli and the fatigue effect during semi-automated kinetic perimetry (SKP). DESIGN Prospective case series; setting: university hospital. PARTICIPANTS 58 patients with severe visual field loss: 21 with glaucoma, 18 with retinitis pigmentosa, and 19 with postchiasmal visual pathway lesions. ...

متن کامل

Statokinetic Dissociation (Riddoch Phenomenon) in a Patient with Homonymous Hemianopsia as the First Sign of Posterior Cortical Atrophy

We report a 60-year-old woman with posterior cortical atrophy (PCA) who presented with left homonymous hemianopsia persisting for 5 years; the patient's condition was observed using static, but not kinetic, perimetry. This statokinetic dissociation of hemianopsia, which is often called Riddoch syndrome, might have been caused by a dysfunction of the right primary visual and visual association c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Vision Research

دوره 46  شماره 

صفحات  -

تاریخ انتشار 2006