Evaluation of sciatic nerve function after ultrasonic and electrocautery muscle dissection: an electromyographic study.
نویسندگان
چکیده
BACKGROUND Minimally invasive surgery has been developed with various innovative surgical tools. Ultrasonic (US) blades have been introduced as an alternative to conventional electrocautery (EC) monopolar device. The purpose of the present study was to evaluate the effects of surgical devices used for muscle dissection close to peripheral nerves on motor nerve function using electromyographic (EMG) recordings. MATERIALS AND METHODS A total of 24 rats were used in this study. The rats were assigned to the following three groups: Control (n = 8), EC (n = 8), and US (n = 8). A stimulus electrode was placed under the sciatic nerve at a sciatic notch. A pair of recording electrodes was implanted into the midbelly regions of the gastrocnemius muscle. To evoke compound muscle action potentials (CMAPs), 3-V stimuli with 0.3-ms duration were applied to the sciatic nerve at a frequency of 1 Hz. After the recording of the baseline, a monopolar surgical device (EC or US) was applied to cut the muscle 10 mm in length and 2 mm away on both sides of the sciatic nerve. Amplitude and latency of the evoked CMAPs were measured. CMAPs were monitored until 3 hours after the device application. RESULTS The EC device caused a marked drop in the amplitude of CMAP with no recovery at the end of the experiment. In the US group, the amplitude of CMAP was stable and constant CMAP over 3 hours, similar to the control group could be measured. In all three groups, the latency of CMAP showed no significant changes through the experiment. CONCLUSION The study showed that the EC device resulted in injury to several motor units in the sciatic nerve. The US device may be a safe tool for muscle dissection around peripheral nerves.
منابع مشابه
Relationship between calcium circulation-related factors and muscle strength in rat sciatic nerve injury model
Objective(s): The purpose of this study is to investigate the indication function of the calcium circulation-related factors on the damage to muscle strength and contraction function after nerve injury. The target factors include ryanodine receptor (RyR), inositol-1,4,5-triphosphate receptor (IP3R), phospholamban (PLN), cryptocalcitonin (CASQ), ATPase and troponin C (T...
متن کاملAcute and subacute effects of the ultrasonic blade and electrosurgery on nerve physiology
Ultrasonic blades have been shown to cause less acute electrophysiological damage when applied near nerves than monopolar electrosurgery (ES). This study was performed to determine whether the acute nerve damage observed for ES, as well as the relative lack of damage observed for ultrasonic dissection, extends through a subacute timeframe. Muscle incisions were made in rat with the Harmonic(®) ...
متن کاملFunctional, Histomorphometrical and Immunohistochemical Assessment of Sciatic Nerve Regeneration through Inside-Out Vein Graft in Rat
Objective- Comprehensive functional, histomorphometrical and immunohistochemical assessment of sciatic nerve regeneration through an inside-out vein graft in rat. Design- Experimental in vivo study. Animals- Fifty- four healthy male White Albino rats. Procedures- The rats were divided into three experimental groups (n=18), randomly: Sham-operation (NC), Transected control (TC) and Inside-out ve...
متن کاملP49: The Evaluation of Aqueous Extract of Glycyrrhiza Glabra on Nerve Recovery in the Rat after Sciatic Nerve Injury
Peripheral nerve injury requires a long recovery period, and recovery, once attained, usually is incomplete. Inflammatory procedures may inhibit functional recovery after nerve injury and produce cell death in both the central nervous system and the peripheral nervous system. Since the glycyrrhiza glabra extract has anti-inflammatory effects, it could reduce the severity of injury. The aim of t...
متن کاملBridging Small-Gap Peripheral Nerve Defect Using Silicone Rubber Chamber in the Rat Sciatic Nerve Transection Model
Despite promising results observed using silicone rubber chamber, no previous comprehensive work was performed on behavior of the conduit. Present study aimed at further functional, histomorphometrical and immunohistochemical assessment of nerve regeneration in the same animal along a 10-mm rat sciatic nerve gap. Fifty- four male Wistar rats were divided into three experimental groups (n = 1...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of neurological surgery. Part A, Central European neurosurgery
دوره 76 2 شماره
صفحات -
تاریخ انتشار 2015