Effect of Reinforcement Using Stainless Steel Mesh, Glass Fibers, and Polyethylene on the Impact Strength of Heat Cure Denture Base Resin - An In Vitro Study

نویسندگان

  • H B Mallikarjuna Murthy
  • Sharaz Shaik
  • Harleen Sachdeva
  • Sumit Khare
  • Satheesh B Haralur
  • K T Roopa
چکیده

BACKGROUND The impact strength of denture base resin is of great concern and many approaches have been made to strengthen acrylic resin dentures. The objective of this study was to compare the impact strength of the denture base resin with and without reinforcement and to evaluate the impact strength of denture base resin when reinforced with stainless steel mesh, glass fiber, and polyethylene fibers in the woven form. MATERIALS AND METHODS The specimens (maxillary denture bases) were fabricated using a standard polyvinylsiloxane mold with conventional heat cured polymethyl methacrylate resin. The specimens were divided into four groups (n = 10). Group I specimens or control group were not reinforced. Group II specimens were reinforced with stainless steel mesh and Group III and Group IV specimens were reinforced with three percent by weight of glass fibers and polyethylene fibers in weave form respectively. All the specimens were immersed in water for 1-week before testing. The impact strength was measured with falling weight impact testing machine. One-way analysis of variance and Tukey's post-hoc test were used for statistical analysis. RESULTS Highest impact strength values were exhibited by the specimens reinforced with polyethylene fibers followed by glass fibers, stainless steel mesh, and control group. CONCLUSIONS Reinforcement of maxillary complete dentures showed a significant increase in impact strength when compared to unreinforced dentures. Polyethylene fibers exhibit better impact strength followed by glass fibers and stainless steel mesh. By using pre-impregnated glass and polyethylene fibers in woven form (prepregs) the impact strength of the denture bases can be increased effectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparative Evaluation of Effect of Reinforced Autopolymerizing Resin on the Flexural Strength of Repaired Heat-polymerized Denture Base Resin before and after Thermocycling

Aims and Objective Denture fractures are a common problem in clinical practice. Despite the use of different reinforcement materials (metal wires, metal plates, and various types of fibers) for denture repairs, recurrent fractures are still common. The purpose of this study was to compare the maximum flexural loads of the heat-polymerized denture base resin when repaired with autopolymerizing r...

متن کامل

Effect of fiber reinforcement on impact strength of heat polymerized polymethyl methacrylate denture base resin: in vitro study and SEM analysis

PURPOSE The aim of this in-vitro investigation was to describe the effect of reinforcement with different fibers on impact strength of heat polymerized polymethyl methacrylate (PMMA) denture base resin and to analyze the effect of surface treatment of the fibers on the impact strength. MATERIALS AND METHODS The specimens were fabricated from the dies formed as per standard ASTM D4812. 2% by w...

متن کامل

Flexural strength of heat-polymerized polymethyl methacrylate denture resin reinforced with glass, aramid, or nylon fibers.

STATEMENT OF PROBLEM Despite the favorable properties of conventional PMMA used as a denture base material, its fracture resistance could be improved. PURPOSE This in vitro study was performed to determine whether the flexural strength of a commercially available, heat-polymerized acrylic denture base material could be improved through reinforcement with 3 types of fibers. MATERIAL AND METH...

متن کامل

The effect of different fiber reinforcements on flexural strength of provisional restorative resins: an in-vitro study

PURPOSE The aim of this study was to compare the flexural strength of polymethyl methacrylate (PMMA) and bis-acryl composite resin reinforced with polyethylene and glass fibers. MATERIALS AND METHODS Three groups of rectangular test specimens (n = 15) of each of the two resin/fiber reinforcement were prepared for flexural strength test and unreinforced group served as the control. Specimens w...

متن کامل

The effect of different reinforcements on the fracture toughness of materials for interim restorations.

STATEMENT OF PROBLEM Fracture of an interim fixed partial denture (FPD) may jeopardize the success of the interim prosthodontic treatment phase and cause patient discomfort. PURPOSE The purpose of this study was to compare the fracture toughness of a polymethyl methacrylate (PMMA) resin and a bis-acryl composite (BAC) resin reinforced with stainless steel wire, glass fiber, and polyethylene f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2015