High Dose Rate Brachytherapy in the Treatment of cervical cancer: preliminary experience with cobalt 60 Radionuclide source—A Prospective Study
نویسندگان
چکیده
UNLABELLED Iridium-192 is widely used for high-dose rate brachytherapy. Co-60 source with similar geometric and dosimetric properties are now available. It has a longer half life but higher energy than Iridium-192. If Co-60 source can produce similar results, it will be more economical for low resource settings. OBJECTIVE To evaluate the acute gastrointestinal and genitourinary toxicity associated with Co-60 source in the brachytherapy of cervical cancer. METHODS Seventy patients with cervical cancer received 45 Gy in 22 fractions of pelvic external beam radiotherapy and 19.5 Gy in 3 fractions of HDR with Co-60 source using tandem and ring applicators with 6 courses of cisplatin 50 mg/m(2) and 5 fluorouracil 1000 mg/m(2) every 3 weeks Toxicity was scored using NCI-CTC version 4.0. RESULTS The median total BED (Gy(10)) for tumor was 86.2 (84.4-88.8) while that for rectum (BED Gy(3)) was 124.4 (120-133). Two patients (3%) had grade 3 gastrointestinal toxicity while all others had ≤grade 2 toxicity and this is comparable with previous results. CONCLUSION Co-60 as HDR brachytherapy source is tolerable and is economical for low resource settings.
منابع مشابه
Comparison the treatment time of cobalt and iridium sources in HDR brachytherapy
Introduction: The use of long-half-life Cobalt source instead of iridium source will be very helpful in HDR brachytherapy for treatment of cervical cancer. The aim of this study was compared the treatment time with cobalt and iridium source in brachytherapy for treatment of cervical cancer using Tandem-ovoid applicator. Materials and Methods: In this study, 19...
متن کاملMonte Carlo calculation of shielded colpostat effect on rectum received dose in high dose rate brachytherapy with Cobalt-60 sources
Background: In the current study the effect of shielded colpostat on rectum received dose was calculated in cervical brachytherapy using Monte Carlo (MC) method. Materials and Methods: Two 60Co sources of GZP6 brachytherapy unit used for intracavitary treatments were simulated using MCNPX Monte Carlo code. Also the two types of colpostats including shielded and unshielded were simulated inside ...
متن کاملEvaluation of dose distribution and dose gradient in brachytherapy cylindrical applicators using a dedicated Phantom for Iridium-192 and Cobalt-60 HDR sources
Introduction: A study was performed to evaluate radiation dose distribution and dose gradient around cylindrical applicators for high-dose-rate (HDR) brachytherapy systems with 192Ir, 60Co brachytherapy source applied for rectal and vaginal cancers treatments. Materials and Methods: Two additional computed tomography (CT) based plans were generated using a ...
متن کاملA Specific Patient Quality Assurance (PSQA) procedure for a Co-60 source based High Dose Rate Brachytherapy
Introduction: In radiation therapy, accurate dose determination and precise dose delivery to the tumor are directly associated with better treatment outcomes in terms of higher tumor control and lower post radiation therapy complications. The current study aims the development and clinical application of the Patient Specific Quality Assurance (PSQA) procedures for nasopharyngea...
متن کاملدرمان داخل حفرهای در مبتلایان سرطان سرویکس: پرتودهی با دوز متوسط در یک مطالعه آیندهنگر
Background: Treatment of cervical carcinoma is routinely performed with Low Dose Rate (LDR) brachytherapy, but Brachytherapy in our department is done with Medium Dose Rate (MDR) due to the technical characteristics of the machine available here. Thus we decided to evaluate the results of this treatment in our department in a prospective study. Methods: Between March 2006 and July 2008, 140 pa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 4 شماره
صفحات -
تاریخ انتشار 2010