Practicality of wavelength selection to improve signal-to-noise ratio in near-infrared spectroscopy.
نویسندگان
چکیده
Near-infrared spectroscopy (NIRS), which can be used to detect changes in the concentration of oxygenated hemoglobin (oxy-Hb) and deoxygenated hemoglobin (deoxy-Hb) in tissue by using illumination at two different wavelengths, is often applied to noninvasive measurements of human brain functions. It is common to use two wavelengths that are on opposite sides of the point where the optical absorptions of oxy- and deoxy-Hb are equal (about 800 nm) but an optimal wavelength pair has not yet been determined. In this study, we conducted simultaneous recordings at five wavelengths (678, 692, 750, 782, and 830 nm) to determine the best wavelength for pairing with 830 nm. A theory suggests that pairing a shorter wavelength with 830 nm can provide more sensitivity because of the larger difference in absorption coefficients of hemoglobin between two wavelengths. The changes measured in four cortical areas (frontal, occipital, parietal, and temporal) showed that the noise level when the 678-, 692-, and 750-nm wavelengths were paired with 830 nm was usually lower than when the 782-nm wavelength was paired with 830 nm, which is consistent with theoretical prediction. Moreover, the signal-to-noise ratios (S/Ns) and wavelength dependencies of the power detected in all areas and subjects together suggest that the 692-nm pairing had the highest S/N. This suggests that the optimal wavelengths depend on not only the difference in the absorption coefficients of hemoglobin but also on the optical properties in the measurement area, which affect the strength of the attenuation data. The 692-nm wavelength is thus a more optimal choice than wavelengths around 780 nm for pairing with 830 nm to measure Hb changes induced by cortical activation. The improved S/N enables more sensitive statistical analysis, which is essential to functional mapping with NIRS.
منابع مشابه
Pretreatment and Wavelength Selection Method for Near-Infrared Spectra Signal Based on Improved CEEMDAN Energy Entropy and Permutation Entropy
The noise of near-infrared spectra and spectral information redundancy can affect the accuracy of calibration and prediction models in near-infrared analytical technology. To address this problem, the improved Complete Ensemble Empirical Mode Decomposition with Adaptive Noise (CEEMDAN) and permutation entropy (PE) were used to propose a new method for pretreatment and wavelength selection of ne...
متن کاملInfrared near-field spectroscopy of trace explosives using an external cavity quantum cascade laser.
Utilizing a broadly-tunable external cavity quantum cascade laser for scattering-type scanning near-field optical microscopy (s-SNOM), we measure infrared spectra of particles of explosives by probing characteristic nitro-group resonances in the 7.1-7.9 µm wavelength range. Measurements are presented with spectral resolution of 0.25 cm(-1), spatial resolution of 25 nm, sensitivity better than 1...
متن کاملFrequency-modulation spectroscopy with blue diode lasers.
Frequency-modulation spectroscopy provides ultrasensitive absorption measurements. The technique is especially adaptable to diode lasers, which can be modulated easily, and has been used extensively in the near-infrared and infrared spectral regions. The availability of blue diode lasers now means that the accessible wavelength region can be increased. We successfully demonstrate wavelength-mod...
متن کاملEvidence for variable outflows in the Young Stellar Object V 645 Cygni
Aims. As part of the Red MSX Source Survey of Massive Young Stellar Objects (MYSOs) we have conducted multi-wavelength follow up observations of the well-known object. We present our data on this object, whose near-infrared spectrum is exceptional and place these in context with previous observations Methods. Our observations of V645 Cyg included near/mid infrared imaging observations, 13 CO 2-...
متن کاملOptimisation of Wavelength Modulated Raman Spectroscopy: Towards High Throughput Cell Screening
In the field of biomedicine, Raman spectroscopy is a powerful technique to discriminate between normal and cancerous cells. However the strong background signal from the sample and the instrumentation affects the efficiency of this discrimination technique. Wavelength Modulated Raman spectroscopy (WMRS) may suppress the background from the Raman spectra. In this study we demonstrate a systemati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- NeuroImage
دوره 21 4 شماره
صفحات -
تاریخ انتشار 2004