Chromium and cobalt ion release following the Durom high carbon content, forged metal-on-metal surface replacement of the hip.
نویسندگان
چکیده
We evaluated the concentrations of chromium and cobalt ions in blood after metal-on-metal surface replacement arthroplasty using a wrought-forged, high carbon content chromium-cobalt alloy implant in 64 patients. At one year, mean whole blood ion levels were 1.61 microg/L (0.4 to 5.5) for chromium and 0.67 microg/L (0.23 to 2.09) for cobalt. The pre-operative ion levels, component size, female gender and the inclination of the acetabular component were inversely proportional to the values of chromium and/or cobalt ions at one year postoperatively. Other factors, such as age and level of activity, did not correlate with the levels of metal ions. We found that the levels of the ions in the serum were 1.39 and 1.37 times higher for chromium and cobalt respectively than those in the whole blood. The levels of metal ions obtained may be specific to the hip resurfacing implant and reflect its manufacturing process.
منابع مشابه
Metal ion release from bearing wear and corrosion with 28 mm and large-diameter metal-on-metal bearing articulations: a follow-up study.
We have updated our previous randomised controlled trial comparing release of chromium (Cr) and cobalt (Co) ions and included levels of titanium (Ti) ions. We have compared the findings from 28 mm metal-on-metal total hip replacement, performed using titanium CLS/Spotorno femoral components and titanium AlloFit acetabular components with Metasul bearings, with Durom hip resurfacing using a Meta...
متن کاملOne-year prospective comparative study of three large-diameter metal-on-metal total hip prostheses: serum metal ion levels and clinical outcomes.
INTRODUCTION The good clinical outcomes and low wear obtained with 28-mm metal-on-metal implants for total hip replacement prompted the development of large-diameter heads that more closely replicated the normal hip anatomy, with the goal of improving prosthesis stability. However, the blood release of metal ions due to wear at the bearing surfaces and the high rate of groin pain seen with larg...
متن کاملElevated Cobalt, Chromium and Molybdenum Levels in Peripheral Blood Have No Effect on the Development of Heterotopic Ossifications after Metal-on-Metal Total Hip Arthroplasty
Metal debris from metal-on-metal (MoM) total hip arthroplasties (THA) has been suspected to cause periprosthetic heterotopic ossifications (HO). We determined the influence of disseminated cobalt, chromium and molybdenum on the development of HO. Native blood samples from patients with 86 high-carbon and 16 low-carbon Co28Cr6Mo articulations were analysed by highresolution inductively coupled p...
متن کاملFailure of total hip implants: metals and metal release in 52 cases.
BACKGROUND The pathogenesis of total joint replacement failure is multifactorial. One hypothesis suggests that corrosion and wear of alloys result in metal ion release, which may then cause sensitization and even implant failure, owing to the acquired immune reactivity. OBJECTIVES To assess cobalt, nickel and chromium(VI) release from, and the metal composition of, failed metal-on-ethylene to...
متن کاملEvaluation of the method for analyzing chromium, cobalt and titanium ion levels in the blood following hip replacement with a metal-on-metal prosthesis.
High-resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) can be used to measure metal ion levels in whole blood, although the accuracy and repeatability of this method is not yet known in the clinical setting. In this study, chromium, cobalt and titanium ion levels were measured in three whole blood samples, each collected at the same moment from 101 patients undergoing total hi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 89 4 شماره
صفحات -
تاریخ انتشار 2007