Examination of four different instruments for measuring blood lactate concentration.
نویسندگان
چکیده
Information on the performance of different instruments used to measure blood lactate concentration is incomplete. We therefore examined instruments from Yellow Springs Instruments (YSI 23L and YSI 1500) and three cheaper and simpler instruments: Dr. Lange's LP8+, Lactate Pro from Arkray in the KDK corporation and Accusport from Boehringer Mannheim. First, a number of blood samples were analysed by standard enzymatic photofluorometry (our reference method) and, in addition, by one or more of the instruments mentioned above. Second, measurements using two or more identical instruments were compared. Third, since Lactate Pro and Accusport are small (approximately 100 g, pocket-size), battery-driven, instruments that could be used for outdoor testing, the performance of these instruments was examined at simulated altitudes (O2 pressure of <10 kPa) and at temperatures below -20 degrees C, while screening the instruments as much as possible from the cold. Most of the different instruments showed systematically too high or too low values (10-25% deviation). The observed differences between instruments may affect the "blood lactate threshold" by 2-5%. We found different readings between "equal" YSI 1500 instruments, while we could see no difference when comparing the other instruments of the same type. Lactate Pro gave reliable results at both -21+/-1 degrees C and at simulated altitude. Accusport gave reliable results in the cold, but 1.85+/-0.08 mmol L(-1) (mean+/-SD) too high readings at the simulated altitude. Of the three simpler instruments examined, the Lactate Pro was at least as good as the YSI instruments and superior to the other two.
منابع مشابه
Exogenous Ketone Supplement Ingestion And Submaximal Exercise Response in Trained, Male Cyclists: A Randomised, Double-blind Study
Background. The acute ingestion of ketone body supplements can improve exercise responses such as oxygen consumption and blood lactate. Additionally, ketone body supplements show increases in circulating βhb concentration, matching those of someone in a state of nutritional ketosis. Studies testing ketone body supplements have reported different results in exercise response and varying gastroin...
متن کاملA method-comparison study regarding the validity and reliability of the Lactate Plus analyzer
OBJECTIVES The aims of this study were to: (1) determine the validity and reliability of the Nova Biomedical Lactate Plus portable analyzer, and quantify any fixed or proportional bias; (2) determine the effect of any bias on the determination of the lactate threshold and (3) determine the effect that blood sampling methods have on validity and reliability. DESIGN In this method comparison st...
متن کاملEffects of silver nanoparticle on lactate dehydrogenase activity and histological changes of heart tissue in male wistar rats
Background & Objective: The silver nanoparticles are important in many applications of nanoparticles on human health . The toxicity of silver nanoparticles are not well documented yet. The aim of this study was to investigate the effect of silver nanoparticles on lactate dehydrogenase activity and histological changes in heart tissue. Materials &Methods: In this study, 40 adult male wistar ra...
متن کاملLactate and lactic acidosis
These biosensors are now incorporated into modern blood gas analyzers and other point-of-care analytical instruments, allowing lactate measurement by nonlaboratory staff on a drop (100 μL) of blood within a minute or two. Whilst blood lactate concentration is invariably raised in those with significant tissue hypoxia, it can also be raised in a number of conditions not associated with tissue hy...
متن کاملAssessment of Photoplethysmography Method in Extraction of Hemoglobin Concentration
Background: The importance of continuous monitoring along with rapid and accurate notification of changes in blood components such as hemoglobin concentration, especially in acute situations, encourages researchers to use non-invasive methods for measuring.Objective: This study was aimed to investigate the correlation between hemoglobin concentration and photoplethysmogram (PPG) and the p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Scandinavian journal of clinical and laboratory investigation
دوره 60 5 شماره
صفحات -
تاریخ انتشار 2000