Sensitive D-amino acid biosensor based on oxidase/peroxidase system mediated by pentacyanoferrate-bound polymer.
نویسندگان
چکیده
A sensitive d-amino acid oxidase (DAAO)/peroxidase (POD) bienzyme biosensor is constructed, in which pentacyanoferrate-bound poly(1-vinylimidazole) polymer (PVI[Fe(CN)5]) is selected as a mediator. Reductive current of PVI[Fe(CN)5] related to the H2O2 concentration generated in the DAAO reaction was measured at -0.1V vs. Ag|AgCl with DAAO/POD/PVI[Fe(CN)5]-modified electrode. The result revealed that PVI[Fe(CN)5] is suitable as a mediator for this bienzyme system due to its appropriate formal potential and its extremely low reactivity against DAAO. The stability of DAAO was improved by adding free flavin adenine dinucleotide and the electrode composition was optimized for the detection of d-alanine. Nafion and ascorbate oxidase-immobilized films worked successfully to prevent severe interference from uric acid and ascorbic acid. The low detection limits of d-alanine (2μM) and d-serine (2μM) imply its possibility for the determination of extremely low concentration of d-amino acids in physiological fluids. The proposed bienzyme biosensor is proved to be capable of detecting d-amino acids in urine.
منابع مشابه
Creatinine Biosensor Based on Reductive H2O2 Detection Using Pentacyanoferrate-bound Polymer
Creatinine is the final product of creatine metabolism in muscle of mammals, and mainly filtered out of blood in kidneys. The creatinine levels are related to the state of renal function, thyroid malfunction and muscular disorders. This indicates the importance of creatinine measurements in blood or urine. The current clinical determination of creatinine is based on Jaffe reaction [1]. However,...
متن کاملAmperometric biosensor based on reductive H2O2 detection using pentacyanoferrate-bound polymer for creatinine determination.
Pentacyanoferrate-bound poly(1-vinylimidazole) (PVI[Fe(CN)5]) was selected as a mediator for amperometric creatinine determination based on the reductive H2O2 detection. Creatinine amidohydrolase (CNH), creatine amidohydrolase (CRH), sarcosine oxidase (SOD), peroxidase (POD), and PVI[Fe(CN)5] were crosslinked with poly(ethylene glycol) diglycidyl ether (PEGDGE) on a glassy carbon (GC) electrode...
متن کاملA Simple and Fast Method for Detecting Glucose in Wines Using a Redox Polymer-Based Amperometric Biosensor
In our quest for a simple and fast method to detect glucose in wines, a redox polymer (RP)-based amperometric biosensor was developed. The biosensor consists of glucose oxidase and horseradish peroxidase (as recognition tandem), an Os-based RP (as electron transfer mediator), poly(ethylene glycol) diglycidyl ether (as cross-linking agent), and a graphite electrode (as transducer). Each building...
متن کاملThe potential use of hydrazine as an alternative to peroxidase in a biosensor: comparison between hydrazine and HRP-based glucose sensors.
The potential use of hydrazine sulfate was examined for the catalytic reduction of enzymatically generated H2O2 in a biosensor system. The performance of the hydrazine-based sensor was compared with an HRP-based glucose sensor as a model of a biosensor. Hydrazine and HRP were covalently immobilized onto a conducting polymer layer with glucose oxidase. The direct electron transfer reactions of t...
متن کاملFabrication of a Sulfite Biosensor by the Use of Conducting Polymer
In this research, an enzyme modified electrode has been produced during the electropolymerization of aniline through incorporation of sulfite oxidase into a conducting polymer. Then the bioelectrochemical response of resulted sulfite biosensor was investigated at different experimental conditions. Study of the stability of the resulted sulfite biosensor revealed that formation of a passive...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Biosensors & bioelectronics
دوره 47 شماره
صفحات -
تاریخ انتشار 2013