Rates of glaucomatous visual field change before and after transscleral cyclophotocoagulation: a retrospective case series
نویسندگان
چکیده
BACKGROUND The primary goal of glaucoma treatment is to lower and control intraocular pressure (IOP) and thereby prevent functional deterioration. For glaucomas that are refractory to medical and incisional surgical therapies, transscleral diode cyclophotocoagulation (TCP) is a well-established procedure to effectively decrease IOP. This study investigated rates of visual field (VF) change in patients with glaucoma before and after TCP. METHODS This retrospective case series investigated rates of VF changes in glaucoma patients before and after they underwent TCP. At least four VF examinations were required, two before and two after surgery. VF examinations were performed using standard automated perimetry and rates of change were calculated by linear regression analysis of mean deviation (MD) values measured over time. RESULTS A total of 46 eyes of 43 patients were included and followed on average 3.6 years before and 2.1 years after TCP. 67 % of the eyes showed further progression of glaucoma following surgery. Mean preoperative MD change was -0.21 dB/year (SE = 0.08, 95 % CI [-0.06, -0.37]). Postoperatively the mean change was -0.26 dB/year (SE = 0.22 95 % CI [0.38, -0.48]) which results in a difference between pre- and postoperative MD rate of 0.05 dB/year (p = 0.824). The mean MD value was worse after surgery and dropped by 1.73 dB (SE = 0.58, 95 % CI [-0.59, -2.87], p = 0.003). Intraocular pressure (IOP) decreased from 23.2 mmHg (SD = 4.67) before TCP to 14.3 mmHg (SD = 3.17) after TCP (p < 0.001). For each 1 mmHg of IOP reduction after surgery, postoperative rate of VF loss decreased by 0.15 dB/year. CONCLUSION Rates of glaucomatous visual field loss did not significantly change after TCP and the majority of the eyes showed further progression of glaucoma after surgery. Mean MD value was considerably lower after TCP.
منابع مشابه
Long-Term Outcome of Transscleral Diode Laser Cyclophotocoagulation for Refractory Glaucoma
Objective: To study success rate and long term efficacy and complications of the transscleral diode laser Cyclophotocoagulation in refractory glaucoma. Patients and Methods: In a noncomparative interventional case series, eyes of 9 patients with glaucoma resistant to conventional medical and surgical therapies were treated with transscleral diode laser Cyclophotocoagulation from 2004 to 2007. C...
متن کاملMicropulse versus continuous wave transscleral diode cyclophotocoagulation in refractory glaucoma: a randomized exploratory study.
BACKGROUND The aim of this study was to compare the efficacy and safety of micropulse and continuous wave diode transscleral cyclophotocoagulation in refractory glaucoma. DESIGN Randomized, comparative, exploratory study in a tertiary hospital setting. PARTICIPANTS Patients with refractory, end-stage glaucoma. METHODS Forty-eight patients were randomized to either treatment. The intraocul...
متن کاملMicropulse transscleral diode laser cyclophotocoagulation in the treatment of refractory glaucoma.
BACKGROUND Transscleral diode laser cyclophotocoagulation (TSCPC) is an established method of treatment for refractory glaucoma, but is associated with significant complications. This study evaluates the efficacy and safety of a new form of TSCPC using micropulse diode laser and trans-pars plana treatment with a novel contact probe. METHODS Prospective interventional case series of 40 eyes of...
متن کاملNeodymium-YAG transscleral cyclophotocoagulation. The role of pigmentation.
Using a rabbit model we investigated the role of pigmentation of the ciliary body in obtaining ciliodestruction by neodymium-YAG transscleral cyclophotocoagulation. There was marked destruction of the ciliary body in pigmented rabbit eyes, but no histologic effect was observed in albino rabbit eyes. These findings suggest that pigmentation of the ciliary body is important for obtaining the desi...
متن کاملEvaluation of cyclophotocoagulation effects with 1310-nm contact optical coherence tomography.
PURPOSE The aim of this pilot study was to evaluate whether contact optical coherence tomography (OCT) allows visualization of the effects of cyclophotocoagulation. METHODS In this pilot study, transscleral contact OCT images (1310-nm wavelength) were generated prior to and immediately after conventional transscleral diode laser cyclophotocoagulation in three eyes of three patients who were s...