Digital Radiography with Computerized Conventional Monitors Compared to Medical Monitors in Vertical Root Fracture Diagnosis

نویسندگان

  • Maryam Tofangchiha
  • Mamak Adel
  • Mahin Bakhshi
  • Mahsa Esfehani
  • Pantea Nazeman
  • Mojgan Ghorbani Elizeyi
  • Amir Javadi
چکیده

INTRODUCTION Vertical root fracture (VRF) is a complication which is chiefly diagnosed radiographically. Recently, film-based radiography has been substituted with digital radiography. At the moment, there is a wide range of monitors available in the market for viewing digital images. The present study aims to compare the diagnostic accuracy, sensitivity and specificity of medical and conventional monitors in detection of vertical root fractures. MATERIAL AND METHODS In this in vitro study 228 extracted single-rooted human teeth were endodontically treated. Vertical root fractures were induced in 114 samples. The teeth were imaged by a digital charge-coupled device radiography using parallel technique. The images were evaluated by a radiologist and an endodontist on two medical and conventional liquid-crystal display (LCD) monitors twice. Z-test was used to analyze the sensitivity, accuracy and specificity of each monitor. Significance level was set at 0.05. Inter and intra observer agreements were calculated by Cohen's kappa. RESULTS Accuracy, specificity and sensitivity for conventional monitor were calculated as 67.5%, 72%, 62.5% respectively; and data for medical grade monitor were 67.5%, 66.5% and 68% respectively. Statistical analysis showed no significant differences in detecting VRF between the two techniques. Inter-observer agreement for conventional and medical monitor was 0.47 and 0.55 respectively (moderate). Intra-observer agreement was 0.78 for medical monitor and 0.87 for conventional one (substantial). CONCLUSION The type of monitor does not influence diagnosis of vertical root fractures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Diagnostic Accuracy of Cone Beam Computed Tomography and Digital Radiography for Detection of Vertical Root Fractures with and without Gutta Percha

  Objective: Diagnosis of vertical root fractures (VRFs) is critical in endodontics which most of the times occurs in endodontically treated teeth with root canal fillings such as gutta percha. Despite Cone Beam Computed Tomography (CBCT) has significantly enhanced image quality compared to digital radiography (DR) which aid the diagnosis, artifacts has remained as a problem in VRF detection . ...

متن کامل

Accuracy comparison of CBCT scan and radiography with two different horzental angle in vertical root fracture detection of endodontically treated teeth

Background and Aims: Accurate diagnosis of vertical root fracture (VRF) is a fundamental importance in endodontics. Because of poor prognosis of VRF, digital radiographs with two horizontal angles have limitations in VRF detection. Also, Gutta-percha can produce artifacts that impair CBCT scan accuracy. The aim of this study was to compare accuracy of CBCT and digital radiography system in vert...

متن کامل

Comparison of Accuracy and Observer Agreement in the Detection of Simulated External Root Resorption Using Conventional Digital Radiography and Digitally Filtered Radiography

Introduction: External root resorption is a clinical problem that often cannot be detected clinically. Thus, radiography plays a crucial role in its diagnosis. However, optimal radiographic quality with minimal radiation exposure {2.1 [EN] Verify English word/phrase choice} is an important factor in selecting the appropriate radiographic technique. The aim of this study was the comparison of ac...

متن کامل

ارزیابی دقت نرم افزار کنتراست معکوس در رادیوگرافی دیجیتال جهت تشخیص شکستگی عمودی ریشه دندان (in vitro)

  Background and Aims: Diagnosis of vertical root fractures often poses a clinical dilemma. Diagnosis of VRF in intraoral radiographs, except in cases where the beam is perpendicular to the direction of fracture is difficult. Misdiagnosis often leads to wrong decisions about the design of teeth future treatment plan. The aim of this study was to determine the diagnostic accuracy of reverse cont...

متن کامل

The Effect of Intra-Canal Posts on Diagnostic Accuracy of Cone Beam Computed Tomography and Digital Radiography in Detection of Vertical Root Fractures

Objective: Diagnosis of vertical root fractures (VRFs) is critical in endodontics. Cone Beam Computed Tomography (CBCT)  has significantly enhanced image quality compared to digital radiography (DR) and greatly aids the diagnosis of VRFs but, metal artifacts has remained as a problem in VRF detection.  This study evaluated the effect of intra canal posts on the diagnostic accuracy of CBCT and D...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013