The Population Effective Dose of Medical Computed Tomography Examinations in Taiwan for 2013

نویسندگان

  • Da-Ming Yeh
  • Hui-Yu Tsai
  • Yen-Sheng Tyan
  • Yu-Cheng Chang
  • Lung-Kwang Pan
  • Tou-Rong Chen
چکیده

PURPOSE To evaluate the annual effective dose per capita attributed to computed tomography (CT) examinations in 2013 and to predict the population effective dose from 2000 to 2013 in Taiwan. METHODS A CT examination database collected from 30 hospitals was divided into 22 procedures and classified into six regions: head, neck, chest, abdomen, pelvis, and other, respectively. The effective doses in different regions were evaluated by dose-length product (DLP) multiplied by conversion factors. RESULTS The CT scan dose parameters were collected from 4,407 patients. For the six scanned regions, the percentages of patients scanned were: head (39.8%), neck (3.9%), chest (23.3%), abdomen (26.7%), pelvis (4.8%), and other (1.6%), respectively. The DLPs per patient (mGy·cm/patient) were head (1,071±225), neck (1,103±615), chest (724±509), abdomen (1,315±550), pelvis (1,231±620) and other (1,407±937), respectively. The number of CT examinations increased rapidly, with an average annual growth rate of 7.6%. The number of CT examinations in 2013 was 2.6 times that in 2000. The population effective dose was 0.30 mSv per capita in 2000 and increased to 0.74 mSv per capita in 2013, with an annual growth rate of 7.2%. The growth trend indicates that the effective dose will continue to rise in Taiwan. CONCLUSION Some strategies should be applied to cope with this growth. Defining the CT dose reference level stipulated in official recommendations and encouraging the use of iterative reconstruction imaging instead of filtered back-projection imaging could be a useful method for optimizing the effective dose and image quality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnostic Reference Levels for Computed Tomography Examinations in Iran: A Nationwide Radiation Dose Survey

Introduction: International Commission on Radiological Protection introduced three basic principles of radiation protection, namely justification, optimization, and dose limit. Medical exposure has no dose limits, and generally, diagnostic reference levels are used as a tool for optimization of patient protection. Material and Methods: Dosimetry was performed on 20 CT scanners located in 14 cit...

متن کامل

Patient doses from X-ray computed tomography examinations by a single-array detector unit: Axial versus spiral mode

Background: X-ray computed tomography (CT) examinations deliver a significant amount of radiation doses to patients comparing to conventional radiography examinations. The objective of the current study was to analyze and investigate the average patient received dose from axial and spiral CT exams in a medical imaging center. Material and Methods: In this study, the patient imaging tec...

متن کامل

Estimation of Absorbed and Effective Doses in Organs through Computed Tomography Examinations Using Automatic Exposure Control and Fixed Tube Current Techniques: A Phantom Case Study

Introduction: The study aimed to assess absorbed and effective doses in organs through computed tomography (CT) examinations using automatic exposure control (AEC) and fixed tube current (FTC) techniques. Material and Methods: Scanning parameters were obtained for routine adult CT examinations and used to estimate the organ absorbed and effec...

متن کامل

Optimal timing of computed tomography for assessing lymph nodes after neoadjuvant chemoradiotherapy for rectal cancer

Background: This study assessed the optimal timing of computed tomography for detection of metastatic disease in locoregional lymph nodes in patients with rectal cancer who have undergone chemoradiotherapy. Materials and Methods: This observational retrospective study was performed in a single institution. All patients with locally advanced rectal cancer treated with chemoradiotherapy, followed...

متن کامل

Patient-Specific Radiation Dose and Cancer Risk in Computed Tomography Examinations in Ondo, Nigeria

Introduction: The dose in computed tomography (CT) often approach or exceed the optimum levels, thereby increasing the probability of cancer induction. With wide application of this diagnostic test, it is expedient to determine the effective dose (ED) for each patient to estimate their cancer risk. This study was conducted to investigate the patient-specific dose (PSD) and cancer risk in CT exa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016