Incremental threshold loading: a standard protocol and establishment of a reference range in naive normal subjects.
نویسندگان
چکیده
Incremental threshold loading (ITL) has been proposed as a test of inspiratory muscle strength and endurance. To date, however, there has been no standardized protocol for an ITL test, and no reference range, with different investigators using a variety of different pressure increments in small numbers of subjects. We developed an ITL test using the weighted plunger (WP) principle, which uses standard increments of pressure. In our protocol subjects inspire through the WP generating an initial threshold opening pressure of 10 cmH2O. This pressure is raised at 2 min intervals in increments of 5 cmH2O until they fail to lift the plunger on two consecutive attempted breaths. Sixty healthy volunteers (30 males and 30 females) aged 20-80 yrs performed the ITL test. Twelve subjects (six females and six males) performed the test twice to assess reproducibility and repeatability. Using stepwise multiple linear regression, we regressed the maximum threshold pressure sustained for a full 2 min (Pmax) against age, height, weight and static maximum inspiratory mouth pressure (MIP). Pmax was significantly related to age but not to either height or weight, the regression equation for males was Pmax (cmH2O)=103.8 - (1.0 x age in years), and for females was Pmax (cmH2O)=93.7 - (1.0 x age in years). The within-subject standard deviation for those repeating the ITL test was 5.4 cmH2O. Incremental threshold loading is a simple technique with good reproducibility, which most naive subjects can use without difficulty. By using standard pressure increments and performing the test in a large number of naive subjects, we have established a reference range that should be applicable wherever similar pressure increments are used.
منابع مشابه
Reference Values for Inspiratory Muscle Endurance in Healthy Children and Adolescents
AIMS To generate reference values for two inspiratory muscle endurance (IME) protocols in healthy children and adolescents. MATERIALS AND METHODS This is an observational, cross-sectional study, in healthy children and adolescents from 4 to 18 years of age. Weight, height, maximal inspiratory pressure (MIP) and IME were measured using two protocols. A fixed load of 30% of MIP with a 10% incre...
متن کاملEffect of Intensive Atropine Doses (Rapid Incremental Loading and Titration) for Management of Organophosphorus Pesticide Poisoning: a Case Series
Background:Acute poisoning with organophosphorus (OP) pesticides is a common method of suicide and entails considerable mortality in Bangladesh. The objective of this study was to evaluate the effects and outcomes of a protocol for treatment of OP poisoning that included titrated incremental atropine as loading dose and slow infusion for maintenance. Methods:In this prospective descriptive cas...
متن کاملEstablishment of Reference Interval for Homeostasis Model Assessment of Insulin Resistance in Healthy Adult Males: a Pilot Study in Alexandria Governorate, Egypt
Abstract Objective: Homeostasis model assessment of insulin resistance (HOMA-IR) is a simple and practical method for estimation of insulin resistance (IR), but a reliable reference interval (RI) of HOMA-IR is needed to deduce the threshold level to define IR. This RI has been controversial in different populations and even more divergent when considering factors like age, gender and body mass...
متن کاملReference Interval of Cerebrospinal Fluid-Adenosine Deaminase Enzyme in Apparently Healthy Subjects- A Retrospective Study in India
Background and Aims: The aim of the present study was to re-evaluate the upper limit of normal range (ULN) for adenosine deaminase (ADA) level in cerebrospinal fluid (CSF) of healthy subjects in Indian population. Materials and Methods: Posteriori strategy was used for reference population selection. Individuals whose CSF samples had come to the laboratory of Bhatia Hospital, Mumbai (India) ...
متن کاملDose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran
Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 10 12 شماره
صفحات -
تاریخ انتشار 1997