Structural Behaviour in Fire and Real Design

نویسندگان

  • S. Lamont
  • Dr Barbara
چکیده

A great deal of understanding into the behaviour of composite steel-concrete structures in fire has been developed since the Cardington frame fire tests (UK) 1990s. This has now been broadened so that structures in fire design has a real engineering basis and is not reliant on results from single element testing in the standard furnace. Several projects involving office buildings in the UK and abroad have highlighted the need for developing the understanding of whole frame behaviour in fire. Since 9-11 robust engineering solutions where the response of the building to an event like fire is known are in great demand. The basics of structural mechanics at high temperatures can be used in design to understand many structures with the aid of computer modelling. This paper provides a direct comparison between the structural response of an 11-storey office building now constructed in the city of London, when designed in a prescriptive manner, with applied fire protection on all the load bearing steelwork, and the response of the same structure designed using a performance based approach leaving the majority of secondary steelwork unprotected. The intent is to demonstrate that structural stability during the fire limit state can be maintained in specific cases without relying on passive fire protection. This paper contributes to the field of structural fire engineering by extending the research work previously conducted by the authors to a real design case and addresses the issues raised by approving authorities, insurers and the client when a fire engineered approach is used to calculate structural response to fire. It also demonstrates the use of advanced analysis to understand beam-core connection response in fire, as part of a series of global finite element analyses to ensure that the unprotected structure proposed provides structural stability and maintains compartmentation for the design fires agreed with the necessary stakeholders in this project.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Proposing the simplified model for choosing the method of retrofitting in existing structures against fire risk

Background and objective: According to the necessities in the part 3 of National Building Regulations, design and construction of buildings should be in a way that the structures, according to the type of use, the size and the number of floors, resist long enough to fire, and prevent from destruction of buildings or from spread of fire to adjacent spaces or buildings. For this purpose, it is ne...

متن کامل

Structural behaviour during a vertically travelling fire

This study considers a multi-storey composite frame subject to a fire which travels vertically between three floors. Previousworkhas analysed the behaviour of this structurewhen subject to simultaneous fires on three floors. It highlighted the importance of the cooling regime adopted and the relative axial stiffness of the steel beams to the overall behaviour of the structure. This paper extend...

متن کامل

Threat-Independent Column Removal and Fire-Induced Progressive Collapse: Numerical Study and Comparison

Progressive collapse is defined as the spread of an initial failure from element to element, eventually resulting in the collapse of an entire structure or a disproportionately large part of it. The current progressive collapse analyses and design methods in guidelines and codes focus on the alternate load path method. This method is suitable especially in the case of blast-induced progressive ...

متن کامل

Delamination of Two-Dimensional Functionally Graded Multilayered Non-Linear Elastic Beam - an Analytical Approach

Delamination fracture of a two-dimensional functionally graded multilayered four-point bending beam that exhibits non-linear behaviour of the material is analyzed. The fracture is studied analytically in terms of the strain energy release rate. The beam under consideration has an arbitrary number of layers. Each layer has individual thickness and material properties. A delamination crack is loc...

متن کامل

The trench effect and eruptive wildfires: lessons from the King’s Cross Underground disaster

Fire eruption (also known as ‘blow-up’ or ‘flare-up’) is a very dangerous aspect of wildland fire behaviour. It poses a significant threat to the safety of wildland fire-fighters and complicates the broader problem of wildfire risk management in complex terrain. Despite the seriousness of eruptive fire events, operational wildland fire spread models generally do not account for the possibility ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007