Improved facility and sensitivity in the use of guinea pigs for the isolation of Legionella pneumophila from cooling tower water.
نویسندگان
چکیده
The established criteria for the determination of the optimum time for the sacrifice of guinea pigs inoculated with samples of cooling tower water were found to be inadequate for the detection of low levels of Legionella pneumophila. By ignoring the requirement for fever and by sequentially sacrificing the infected guinea pigs on days 3 through 5 postinoculation, we simplified the procedure, and the sensitivity of detection was improved a great deal.
منابع مشابه
Isolation of Legionella pneumophila from Tehran Hospital Water Samples
Over a Period of three months (summer), 108 samples of water collected from four hospitals in Te-hran. They were taken from numerous potable and non-potable water, including main supply cis-terns, calorifiers, hot and cold tap water, shower, cooling tower and drain of air condition system. Culturing of concentrated and non-concentrated water samples on Buffered Charcoal Yeast Extract (BCYE) Aga...
متن کاملIsolation of Legionella pneumophilia from cooling tower water by filtration.
Methods are described for detection of Legionella pneumophila in cooling tower water or other water sources by direct fluorescent-antibody staining. A procedure for isolation of Legionella bacteria from water samples by guinea pig inoculation is described. Two different serogroups of L. pneumophila were isolated repeatedly from one of the cooling towers.
متن کاملIsolation of Legionella Pneumophila Serogroups 1, 8 & 10 (Causative Agents of Legionnaires\' Disease) from Water Sources in Tehran, Iran
In this survey, 187 samples collected from 9 different sources of water in Tehran such as: water coolers, neonates incubators, water bathes (37° C), little pools in parks or squares, cooling towers, hot or cold water taps, were examined for Legionnaires' disease agents. Inoculating water samples on selective and nonselective media resulted in isolation of several strains of gram negative bact...
متن کاملLegionella spp. in Puerto Rico cooling towers.
Water samples from air conditioning cooling towers receiving different treatment protocols on five large municipal buildings in San Juan, P.R., were assayed for various Legionella spp. and serogroups by using direct immunofluorescence. Several water quality parameters were also measured for each sample. Guinea pigs were inoculated with water samples to confirm pathogenicity and recover viable o...
متن کاملNegative enrichment procedure for isolation of Legionella pneumophila from seeded cooling tower water.
A negative enrichment procedure was developed which was capable of isolating Legionella pneumophila directly from seeded air-conditioning cooling tower water onto laboratory media. This procedure was based on an 8-h incubation under conditions that were bactericidal to the indigenous water microflora but merely bacteriostatic to L. pneumophila.