Comparison of two sperm processing techniques for low complexity assisted fertilization: sperm washing followed by swim-up and discontinuous density gradient centrifugation

نویسندگان

  • Cássio L Fácio
  • Lígia F Previato
  • Ligiane A Machado-Paula
  • Paulo CS Matheus
  • Edilberto Araújo Filho
چکیده

OBJECTIVE This study aimed to assess and compare sperm motility, concentration, and morphology recovery rates, before and after processing through sperm washing followed by swim-up or discontinuous density gradient centrifugation in normospermic individuals. METHODS Fifty-eight semen samples were used in double intrauterine insemination procedures; 17 samples (group 1) were prepared with sperm washing followed by swim-up, and 41 (group 2) by discontinuous density gradient centrifugation. This prospective non-randomized study assessed seminal parameters before and after semen processing. A dependent t-test was used for the same technique to analyze seminal parameters before and after semen processing; an independent t-test was used to compare the results before and after processing for both techniques. RESULTS The two techniques produced decreases in sample concentration (sperm washing followed by swim-up: P<0.000006; discontinuous density gradient centrifugation: P=0.008457) and increases in motility and normal morphology sperm rates after processing. The difference in sperm motility between the two techniques was not statistically significant. Sperm washing followed by swim-up had better morphology recovery rates than discontinuous density gradient centrifugation (P=0.0095); and the density gradient group had better concentration recovery rates than the swim-up group (P=0.0027). CONCLUSION The two methods successfully recovered the minimum sperm values needed to perform intrauterine insemination. Sperm washing followed by swim-up is indicated for semen with high sperm concentration and better morphology recovery rates. Discontinuous density gradient centrifugation produced improved concentration recovery rates.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sperm Preparation Techniques for Artificial Insemination - Comparison of Sperm Washing, Swim Up, and Density Gradient Centrifugation Methods

The Artificial Insemination (AI) is the first option treatment for infertile couples with cervical factor subfertility, mild-moderate male subfertility and unexplained infertility. With the exception of cases in which the use of in vitro fertilization (IVF or ICSI) is strictly due as a consequence of a severe male or female factor, the artificial insemination must be part of a gradual approach ...

متن کامل

P-19: Effect of Three Sperm Preparation Methods on Sperm DNA Integrity and Oocyte Fertilization Rate

Background: Techniques of sperm preparation require centrifugation to separate spermatozoa from the seminal plasma. The centrifugation can induce damage to the spermatozoa and increase reactive oxygen species(ROS) productionspecially in leukospermic speciemens that are associated with impaired function and fertilizing capacity. However in ICSI, fertilization can occure with damage DNA sperm but...

متن کامل

Combination of density gradient centrifugation and swim-up methods effectively decreases morphologically abnormal sperms

Density gradient centrifugation (DGC) and swim-up techniques have been reported for semen preparation in assisted reproductive techniques in humans. We investigated whether semen preparation using a combination of DGC and swim-up techniques could effectively decrease morphologically abnormal human sperms at the ultrastructural level. Semen samples were obtained from 16 infertile males and fract...

متن کامل

Comparison of the effect of different media on the clinical outcomes of the density-gradient centrifugation/swim-up and swim-up methods

OBJECTIVE Sperm must be properly prepared in in vitro fertilization (IVF)-embryo transfer (ET) programs in order to control the fertilization rate and ensure that embryos are of high quality and have appropriate developmental abilities. The objective of this study was to determine the most optimal sperm preparation method for IVF. METHODS Patients less than 40 years of age who participated in...

متن کامل

Comparison of in vitro fertilization outcomes in ICSI cycles after human sperm preparation by density gradient centrifugation and direct micro swim-up without centrifugation

OBJECTIVE The aim of this study was to evaluate the efficacy of a non-expensive, easy and fast technique (direct micro swim-up) for sperm preparation in intracytoplasmic sperm injection (ICSI) treatments without the use of centrifuge. METHODS We carried out a multicentric study in which a total of 140 ICSI-cycles were included. Sibling oocytes were divided into two groups according to semen p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 20  شماره 

صفحات  -

تاریخ انتشار 2016