Comparison of the BacT/Alert PF pediatric FAN blood culture bottle with the standard pediatric blood culture bottle, the Pedi-BacT.

نویسندگان

  • K K Krisher
  • P Gibb
  • S Corbett
  • D Church
چکیده

The performance of the BacT/Alert PF (Organon-Teknika Corp., Durham, N.C.), a new nonvented pediatric FAN blood culture bottle, was compared to that of the original pediatric bottle, the Pedi-BacT, with matched aerobic cultures obtained from two separate facilities. A total of 244 clinically significant isolates were recovered from 4,015 compliant pairs. Among the positive cultures, 170 (70%) isolates were detected in both the BacT/Alert PF and the Pedi-BacT bottles, while 47 (19%) isolates were recovered in the BacT/Alert PF bottle only and 27 (11%) isolates were recovered in the Pedi-BacT bottle only. Although isolation of specific microorganisms was comparable for the two bottles, the total number of organisms recovered by the BacT/Alert PF was greater than that by the Pedi-BacT (P = 0.0272). In addition, more organisms were recovered by the BacT/Alert PF bottle from the blood of patients receiving antimicrobial therapy (P = 0.0180). Overall time to detection was similar for the two bottles; however, a significantly decreased mean time to detection was recorded for yeast from the BacT/Alert PF bottle (22.9 h; P = 0.0001) and staphylococci from the Pedi-BacT bottle (22.5 h; P = 0.0056). One false-negative culture and five false-positive cultures occurred with the Pedi-BacT bottle, compared to one false-positive culture with the BacT/Alert PF bottle. The BacT/Alert PF bottle is a reliable blood culture bottle for pediatric blood culture specimens and may offer improved recovery of microbes from patients on antimicrobial therapy. The use of the nonvented bottle will both facilitate bottle processing and decrease expenditures for materials due to the elimination of the venting needles required for the original vented bottles.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Controlled clinical comparison of new pediatric medium with adsorbent polymeric beads (PF Plus) versus charcoal-containing PF medium in the BacT/alert blood culture system.

We conducted a controlled clinical comparison of PF Plus, the new pediatric medium with adsorbent polymeric beads, versus the charcoal-containing PF medium in the BacT/Alert blood culture system. A total of 2,381 pediatric cultures were enrolled, and 1,703 (71.5%) were deemed to be compliant and acceptable for analysis. Seventy-two cultures (4.2%) had a positive result with 80 clinically signif...

متن کامل

Comparison of the BacT/Alert pediatric blood culture system, Pedi-BacT, with conventional culture using the 20-milliliter Becton-Dickinson supplemented peptone broth tube.

The performance of the Pedi-BacT system, the BacT/Alert (Organon Teknika Corp., Durham, N.C.) pediatric blood culture bottle, was compared with that of a conventional 20-ml supplemented peptone broth tube (Becton-Dickinson Corp., Cockeysville, Md.) (BD system) in matched aerobic cultures. The tubes of the BD system were visually examined daily for 7 days and were subcultured during the first 24...

متن کامل

Rapid PCR detection of methicillin-resistant Staphylococcus aureus and methicillin-sensitive S. aureus samples from charcoal-containing blood culture bottles.

Recent advances in technology have allowed development of automated, rapid, real-time PCR tests that are able to differentiate between methicillin-sensitive Staphylococcus aureus (MSSA) and methicillin-resistant S. aureus (MRSA) in blood cultures. These include the Cepheid Xpert MRSA/SA blood culture assay used with the GeneXpert Dx system (Cepheid, Sunnyvale, CA), which has been found to have ...

متن کامل

Clinical comparison of nonvented aerobic BacT/Alert blood culture bottle and standard aerobic bottle for detection of microorganisms in blood.

The current BacT/Alert standard aerobic (VA) blood culture bottle was redesigned and designated a nonvented aerobic (NVA) culture bottle; this bottle does not require venting. A total of 3,873 sets of blood samples for culture were obtained from adult patients with suspected bacteremia or fungemia. The NVA bottle showed performance equivalent to that of the VA bottle for recovery and speed of d...

متن کامل

Controlled clinical comparison of BacT/alert FA plus and FN plus blood culture media with BacT/alert FA and FN blood culture media.

New blood culture media containing antibiotic-binding polymeric beads have been developed for the BacT/Alert (bioMérieux, Inc., Durham, NC) blood culture system. To assess the performance of these new media, we compared the new BacT/Alert aerobic medium (FA Plus) with resins to BacT/Alert FA medium with activated charcoal and the new BacT/Alert anaerobic medium (FN Plus) to BacT/Alert FN medium...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 39 8  شماره 

صفحات  -

تاریخ انتشار 2001