Investigating the temporal resolution limits of scintillation detection from pixellated elements: comparison between experiment and simulation.
نویسندگان
چکیده
This study investigates the physical limitations involved in the extraction of accurate timing information from pixellated scintillation detectors for positron emission tomography (PET). Accurate physical modeling of the scintillation detection process, from scintillation light generation through detection, is devised and performed for varying detector attributes, such as the crystal element length, light yield, decay time and surface treatment. The dependence of light output and time resolution on these attributes, as well as on the photon interaction depth (DoI) of the annihilation quanta within the crystal volume, is studied and compared with experimental results. A theoretical background which highlights the importance of different time blurring factors for instantaneous ('ideal') and exponential ('realistic') scintillation decay is developed and compared with simulated data. For the case of a realistic scintillator, our experimental and simulation findings suggest that dependence of detector performance on DoI is more evident for crystal elements with rough ('as cut') compared to polished surfaces (maximum observed difference of 64% (25%) and 22% (19%) in simulation (measurement) for light output and time resolution, respectively). Furthermore we observe distinct trends of the detector performance dependence on detector element length and surface treatment. For short crystals (3 × 3 × 5 mm(3)) an improvement in light output and time resolution for 'as cut' compared to polished crystals is observed (3% (7%) and 9% (9%) for simulation (measurement), respectively). The trend is reversed for longer crystals (3 × 3 × 20 mm(3)) and an improvement in light output and time uncertainty for polished compared to 'as cut' crystals is observed (36% (6%) and 40% (20%) for simulation (measurement), respectively). The results of this study are used to guide the design of PET detectors with combined time of flight (ToF) and DoI features.
منابع مشابه
Design of a High-Resolution and High-Sensitivity Scintillation Crystal Array for PET With Nearly Complete Light Collection
Spatial resolution improvements in positron emission tomography (PET) can be achieved by developing detector arrays with finer resolution elements. To maintain high sensitivity and image quality, the challenge is to develop a finely pixellated scintillation crystal array with both high detection efficiency and high light collection. High detection efficiency means the crystals must be relativel...
متن کاملInvestigating the capability of plastic scintillation detectors in design of a muon radiography system by Geant4 code
Imaging and identifying materials with high atomic numbers and densities, especially radioactive materials, is one of the issues that have been especially considered in recent years. Due to some limitations in conventional and old imaging techniques, finding an alternative method is very important. The cosmic muons with an infinite source are one of the sources that have been recently studied f...
متن کاملMethods to extract more light from minute scintillation crystals used in an ultra-high resolution positron emission tomography detector
Recently, there has been great interest in developing finely pixellated position-sensitive scintillation detectors for ultra-high-resolution Positron Emission Tomography (PET) systems designed for breast cancer detection, diagnosis, and staging and for imaging small laboratory animals. We are developing a different high-resolution PET detector design that promotes nearly complete scintillation ...
متن کاملبررسی رفتار آشکارساز سوسوزن آرایه رصدخانه البرز با روش شبیهسازی مونت کارلو در بستر نرمافزاری جیانت۴
For their appropriate temporal resolution, scintillator detectors are used in the Alborz observatory. In this work, the behavior of the scintillation detectors for the passage of electrons with different energies and directions were studied using the simulation code GEANT4. Pulse shapes of scintillation light, and such characteristics as the total number of photons, the rise time and the fallin...
متن کاملGrowth of CsI(Tl) crystals doped with Ca and Tm and investigation of its scintillation characteristics
In this work, the growth of CsI(Tl) crystals as gamma detector was performed using vertical Bridgman method with Ca and Tm co-dopants. For evaluation of the growth crystals, X-Ray Diffraction (XRD), photoluminescence and thermoluminescence spectra as well as recorded gamma spectra were employed. In addition, the scintillation properties including energy resolution, scintillation decay time, abs...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physics in medicine and biology
دوره 56 3 شماره
صفحات -
تاریخ انتشار 2011