Time-course Characterization of High-intensity Focused Ultrasound Exposure Using B-mode Ultrasound Imaging
نویسندگان
چکیده
High-Intensity Focused Ultrasound (HIFU) is an emerging non-invasive surgical technique. HIFU systems are generally designed to deliver a fixed amount of energy to tissue, but because the tissue thermal response is variable across patients and tissue type, this approach can often lead to underdosing or overdosing. In order to improve the dosing precision in HIFU we are investigating real time monitoring of the energy deposition process through high-frequency diagnostic ultrasound imaging. Ultimately the development of monitoring techniques will allow real-time adjustment of energy to obtain optimal treatment. We present results from an exploratory study into the transient response of HIFU exposure in phantoms and animal tissue. The transient response observed in the B-mode ultrasound images is due to a combination of the thermal-acoustic lens effect, thermal expansion of the medium and cavitation. These preliminary experiments will inform the development of new image analysis techniques for determining dosage received in tissue during HIFU exposure.
منابع مشابه
Numerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator
Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...
متن کاملFree hydroxyl radical dosimetry by using 1 MHz low level ultrasound waves
ABSTRACTBackground : In order to quantify effects of ultrasound irradiation parameters under therapeutic condition, especially sonodynamic therapy, it is initially necessary to evaluate inertial cavitation activity in vitro conditions therefore, in this study, the effect of 1 MHz low level ultrasound based on °OH radicals generated by acoustic inertial cavitation in aqueous solution was monit...
متن کاملReview Paper: A Review on Brain Stimulation Using Low Intensity Focused Ultrasound
Brain stimulation techniques are important in both basic and clinical studies. Majority of well-known brain stimulating techniques have low spatial resolution or entail invasive processes. Low intensity focused ultrasound (LIFU) seems to be a proper candidate for dealing with such deficiencies. This review recapitulates studies which explored the effects of LIFU on brain str...
متن کاملIntra-operative ultrasound hand-held strain imaging for the visualization of ablations produced in the liver with a toroidal HIFU transducer: first in vivo results.
The use of hand-held ultrasound strain imaging for the intra-operative real-time visualization of HIFU (high-intensity focused ultrasound) ablations produced in the liver by a toroidal transducer was investigated. A linear 12 MHz ultrasound imaging probe was used to obtain radiofrequency signals. Using a fast cross-correlation algorithm, strain images were calculated and displayed at 60 frames ...
متن کاملComparative study of temperature measurements in ex vivo swine muscle and a tissue-mimicking material during high intensity focused ultrasound exposures.
Tissue-mimicking materials (TMMs) can provide a convenient, stable, and reproducible means for testing high intensity focused ultrasound (HIFU) devices. When TMMs containing thermal sensors are used to measure ultrasound-induced temperature rise, it is important that measurement results reasonably represent those that occur in biological tissue. Therefore the aim of this paper is to compare the...
متن کامل