Room temperature influences output from the Wright jet nebulizer.

نویسندگان

  • J Kongerud
  • V Søyseth
  • B Johansen
چکیده

Standardization of the solute output from the Wright nebulizer is necessary in nonspecific bronchial challenge to obtain reproducible results. Airflow and driving pressure are known determinants of the output. In an epidemiological study, in which day-to-day variations in room temperature occurred, we found the reproducibility of the output from a Wright nebulizer to be outside the range of acceptance. We have, therefore, examined to what extent ambient temperature and humidity might influence the output from three Wright nebulizers. The solute output was linearly correlated not only to flow (r = 0.98) and driving pressure (r = 0.90) but also to room temperature (r = 0.96). The mean output increased approximately 23% when room temperature was increased from 19 to 24 degrees C. This is equivalent to an increase in airflow of more than one litre. Ambient humidity did not influence the nebulizer output. When temperature was included in the calibration procedure, the coefficient of variation of the output decreased from 5 to 2%. This emphasizes the need for calibration of the Wright nebulizer with regard to ambient temperature as well as to airflow and pressure, especially in epidemiological field studies in which large variations of temperature are likely to occur.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Medical nebulizer performance: effects of cascade impactor temperature.

BACKGROUND During operation of a jet nebulizer, the temperature of the nebulizer outlet could decrease by more than 10 degrees C, depending on the nebulizer type and operating conditions, such as driving flow rate and fill volume. The droplet size distribution generated from the nebulizer can be measured by a cascade impactor. However, when the cascade impactor is operated at ambient room tempe...

متن کامل

Jet and ultrasonic nebuliser output: use of a new method for direct measurement of aerosol output.

Output from jet nebulisers is calibrated traditionally by weighing them before and after nebulisation, but the assumption that the weight difference is a close measure of aerosol generation could be invalidated by the concomitant process of evaporation. A method has been developed for measuring aerosol output directly by using a solute (fluoride) tracer and aerosol impaction, and this has been ...

متن کامل

Physicochemical aspects and efficiency of albuterol nebulization: comparison of three aerosol types in an in vitro pediatric model.

BACKGROUND Advances in nebulizer design have produced both ultrasonic nebulizers and devices based on a vibrating mesh (vibrating mesh nebulizers), which are expected to enhance the efficiency of aerosol drug therapy. The aim of this study was to compare 4 different nebulizers, of 3 different types, in an in vitro model using albuterol delivery and physical characteristics as benchmarks. METH...

متن کامل

Quantifying Aerosol Delivery in Simulated Spontaneously Breathing Patients With Tracheostomy Using Different Humidification Systems With or Without Exhaled Humidity.

BACKGROUND Aerosol and humidification therapy are used in long-term airway management of critically ill patients with a tracheostomy. The purpose of this study was to determine delivery efficiency of jet and mesh nebulizers combined with different humidification systems in a model of a spontaneously breathing tracheotomized adult with or without exhaled heated humidity. METHODS An in vitro mo...

متن کامل

A Radiometric Study of Factors Affecting Drug Output of Jet Nebulizers

Jet nebulizers show an unreasonable variation in drug output and nebulization rates that leads to clinical and regulatory problems. Current evaluation methods appear inadequate for the purpose. Our objective was to evaluate Technetium-99m radiometry to study nebulizer parameters and the factors influencing it quantitatively. Drug output, output rate and residual mass and the effect of excipient...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 2 7  شماره 

صفحات  -

تاریخ انتشار 1989