Study of Axial Acceleration Improvement of Stacked Volumetric Optical Disks

نویسندگان

  • Akira INABA
  • Hiroyuki AWANO
چکیده

developed whose read/write characteristics are comparable to 1.2-mm-thick optical disks. The development difficulty of the thin optical disks was the achievement of stable rotation equivalent to 1.2-mm-thick optical disks. This report presents the results of studies conducted to improve the axial accelerations of thin optical disks on 8× speed (27.92 m/s) based on the digital versatile disc recordable (DVD-R) format. Our studies showed improvements of the transparent glass disk stabilizer and the smoothing of the thin optical disk surface. Axial accelerations were improved to a practical level less than 73 m/s based on 8× DVD-R specifi cations.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interlayer cross talk in dual-layer read-only optical disks.

Volumetric optical disks comprising multiple data layers have been proposed to multiply recording density. Owing to the presence of out-of-focus data layers, interlayer cross talk is induced in readout. An optical model was developed to study the readout process and the effect of interlayer cross talk on the readout of dual-layer read-only optical disks. Schemes to improve the readout character...

متن کامل

Three-dimensional reconstruction of the stacked-disk aggregate of tobacco mosaic virus protein from electron micrographs

The three-dimensional structure of the stacked-disk rod of tobacco mosaic virus protein has been recon­ structed to a resolution of about 2 nm from electron microscope images. Closed rings of seventeen protein subunits (compared with 16^ in one turn of the virus helix) are stacked in polar fashion, the stacking being accompanied by an axial perturbation of periodicity 5.3 nm connecting successi...

متن کامل

Three-dimensional reconstruction of the stacked-disk aggregate of tobacco mosaic virus protein from electron micrographs.

The three-dimensional structure of the stacked-disk rod of tobacco mosaic virus protein has been recon­ structed to a resolution of about 2 nm from electron microscope images. Closed rings of seventeen protein subunits (compared with 16^ in one turn of the virus helix) are stacked in polar fashion, the stacking being accompanied by an axial perturbation of periodicity 5.3 nm connecting successi...

متن کامل

Mathematical Modeling of Micropolar Blood Flow in a Stenosed Artery Under the Body Acceleration and Magnetic Field

Blood flow is modeled as non-Newtonian micropolar fluid. The non-linear governing equations of continuum and momentum in the cylindrical coordinate are being discretized using a finite difference approach and have been solved iteratively ,through Crank-Nicolson method. The blood velocity distribution, volumetric flow rate and Resistance to blood flow at the stenosis throat are computed for vari...

متن کامل

Graphics processing unit accelerated optical coherence tomography processing at megahertz axial scan rate and high resolution video rate volumetric rendering.

In this report, we describe how to highly optimize a computer unified device architecture based platform to perform real-time processing of optical coherence tomography interferometric data and three-dimensional (3-D) volumetric rendering using a commercially available, cost-effective, graphics processing unit (GPU). The maximum complete attainable axial scan processing rate, including memory t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009