Coupled absorption filters for thermal detectors.

نویسندگان

  • Yuyan Wang
  • Benjamin J Potter
  • Joseph J Talghader
چکیده

A resonant absorption cavity that couples long-wavelength infrared (LWIR) light into a movable plate has been demonstrated for thermal detectors, especially microbolometers. Each device is continuously tunable over 8.7-11.1 microm by using electrostatic actuation with voltages from 0 to 42 V. The width of the resonance is relatively broad, approximately 1.5 microm, to match the large widths of many spectral features in the LWIR. At an actuation voltage of 45 V, the device switches into a broadband mode with an absorption width of 2.83 microm. This latter mode is used to enhance sensitivity in low-light situations in which little spectral information is present.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Wavelength- or Polarization-Selective Thermal Infrared Detectors for Multi-Color or Polarimetric Imaging Using Plasmonics and Metamaterials

Wavelength- or polarization-selective thermal infrared (IR) detectors are promising for various novel applications such as fire detection, gas analysis, multi-color imaging, multi-channel detectors, recognition of artificial objects in a natural environment, and facial recognition. However, these functions require additional filters or polarizers, which leads to high cost and technical difficul...

متن کامل

Notch Filter Options for ITER Stray Gyrotron Radiation

ITER will have multi megawatt gyrotron systems at 170, 120, and potentially at 60 GHz for ECH, current drive, NTM control, start up, and CTS diagnostics. The ITER environment will therefore have significant background levels of stay radiation at these frequencies that can pose a problem to a number of diagnostic systems. Several deep, narrowband reject filter approaches have been examined. Thes...

متن کامل

Flats: Sbc Data from Thermal Vacuum Testing

The Advanced Camera for Surveys (ACS) has three detectors: a large and a small format CCD (WFC and HRC), and a 1024x1024 MAMA Solar Blind Channel (SBC). During the Thermal Vacuum testing at GSFC in 1999 March, flats with S/N=100 per pixel were obtained for the six SBC filters and two prisms. The pixel-to-pixel P-flats are independent of wavelength to <1%. Because of a temperature dependence in ...

متن کامل

Adaptive thermal compensation of test masses in advanced LIGO

As the first generation of laser interferometric gravitational wave detectors near operation, research and development has begun on increasing the instrument’s sensitivity while utilizing the existing infrastructure. In the Laser Interferometer Gravitational Wave Observatory (LIGO), significant improvements are being planned for installation in ∼2007, increasing strain sensitivity through impro...

متن کامل

Diffractively coupled Fabry-Perot resonator with power-recycling.

We demonstrate the optical coupling of two cavities without light transmission through a substrate. As the all-reflective coupling component, we use a dielectric low-efficiency 3-port diffraction grating. In contrast to a conventional transmissive coupling component, such an all-reflective coupler avoids all thermal effects that are associated with light absorption in the substrate. An all-refl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics letters

دوره 31 13  شماره 

صفحات  -

تاریخ انتشار 2006