An intra-operative positron probe with background rejection capability for FDG-guided surgery.

نویسندگان

  • Seiichi Yamamoto
  • Keiichi Matsumoto
  • Setsu Sakamoto
  • Kazumasa Tarutani
  • Kotaro Minato
  • Michio Senda
چکیده

For radio-guided surgery on tumors using F-18-FDG, detection of annihilation gamma photons emanating from other parts of the body produces background radiation counts and limits its use in clinical situations. To overcome this limitation, we have developed an intra-operative positron probe with background-rejection capability. The positron probe uses a phoswich detector composed of a plastic scintillator and a bismuth germinate (BGO). A positron from a positron emitter such as F-18 is detected by the plastic scintillator and emits annihilation photons. The BGO detects one of the annihilation photons while a photo-multiplier tube (PMT) detects scintillation photons from both scintillators. The decay time differences of these two scintillators are used to distinguish whether the event is a true event where a positron and a following annihilation photon are detected simultaneously, or a background event. In this configuration, only positrons can be selectively detected, even in an environment of high background gamma photon flux. Spatial resolution was 11-mm full width at half maximum (FWHM) 5 mm from the detector surface. Measured sensitivity for the F-18 point source was 2.6 cps/kBq 5 mm from the detector surface. The background count rate was less than 0.5 cps for a 20-cm diameter cylindrical phantom containing 37 MBq of F-18 solution measured on the phantom surface, while the positron count rate was almost linear over a range of approximately 6 kcps. These results indicate that our developed intra-operative positron probe is valuable for radio-guided surgery on tumors using F-18-FDG in a high flux of background annihilation gamma photons.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intra-operative use of PET probe for localization of FDG avid lesions

Localizing positron emission tomography (PET)/computed tomography (CT) findings in heavily scarred surgical fields can be challenging. A high energy gamma probe (PET probe) can be used to guide surgery in those difficult areas. We describe our experience localizing and removing fluorodeoxyglucose (FDG) avid lesions in different body areas. Between 2004 and 2007, we used the PET probe to localiz...

متن کامل

PET probe-guided surgery: applications and clinical protocol

INTRODUCTION Parallel to the advances in diagnostic imaging using positron emission tomography (PET), and availability of new systemic treatment options, the treatment paradigm in oncology has shifted towards more aggressive therapeutic interventions to include cytoreductive techniques and metastasectomies. Intraoperative localization of PET positive recurrent/metastatic lesions can be facilita...

متن کامل

PET Probe-Guided Surgery in Patients with Breast Cancer: Proposal for a Methodological Approach.

BACKGROUND Although it is valuable for detecting distant metastases, identifying recurrence, and evaluating responses to chemotherapy, the role of 18F-fluorodeoxyglucose positron-emission tomography/computed tomography (18F-FDG PET/CT) in assessing locoregional nodal status for initial staging of breast cancer has not yet been well-defined in clinical practice. In the current report, we describ...

متن کامل

PET and MRI-guided focused ultrasound surgery for hypoxic-tissue ablation combined with radiotherapy in solid tumors

Background: The rationale was to develop an ablation approach to destroy regions of tumor resistant to radiation and thus reduce the time required for whole tumor ablation, while improving overall tumor control after radiotherapy. Materials and Methods: The system is composed of a micro positron emission tomography (mPET), 7T magnetic resonance imaging (MRI), and a customized MRI-compatible foc...

متن کامل

A Handheld β+ Probe for Intra-Operative Detection of Radiotracers

A handheld probe for direct positron detection based on scintillators coupled to silicon photomultipliers (SiPMs) is presented in this paper. The battery-powered system is optimised for intra-operative use. It is fully sterilisable and wirelessly connected to a PC running a graphical user interface. Successful pilot clinical trials have shown the use in oncological surgery.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of nuclear medicine

دوره 19 1  شماره 

صفحات  -

تاریخ انتشار 2005