The influence of head and neck position on oropharyngeal leak pressure and cuff position with the flexible and the standard laryngeal mask airway.
نویسندگان
چکیده
UNLABELLED We conducted a randomized, cross-over study of 20 paralyzed anesthetized adult patients to test the hypothesis that oropharyngeal leak pressure and cuff position (assessed fiberoptically) vary with head and neck position for the flexible (FLMA) and standard laryngeal mask airway (LMA). Both devices were inserted into each patient in random order. Oropharyngeal leak pressure and fiberoptic position (including degree of rotation) were documented in four head and neck positions (neutral first, then flexion, then extension and rotation in random order) for each device. The size 5 was used for all patients, and the intracuff pressure was set at 60 cm H2O in the neutral position. All airway devices were inserted at the first attempt. Oropharyngeal leak pressure was similar for the FLMA and LMA in the neutral (22 vs 21 cm H2O), flexed (26 vs 26 cm H2O), and extended positions (19 vs 18 cm H2O) but was slightly higher for the LMA when the head was rotated (19 vs 22 cm H2O; P = 0.04). Compared with the neutral position, oropharyngeal leak pressure for the LMA was higher with flexion (26 vs 21 cm H2O; P = 0.0004) and lower with extension (18 vs 21 cm H2O; P = 0.03) but similar with rotation. Compared with the neutral position, oropharyngeal leak pressure for the FLMA was higher with flexion (26 vs 22 cm H2O; P = 0.0001) and lower with extension (19 vs 22 cm H2O; P = 0.03) and rotation (19 vs 22 cm H2O; P = 0.03). The difference in oropharyngeal leak pressure between flexion and extension was 7 and 8 cm H2O for the FLMA and LMA, respectively. Fiberoptic position was similar between devices and was unchanged by head and neck position. Rotation was not detected fiberoptically. We conclude that there are small changes in oropharyngeal leak pressure but no changes in cuff position in different head and neck positions for the FLMA and LMA. Oropharyngeal leak pressure may be improved by head and neck flexion and by avoiding extension. IMPLICATIONS There are small changes in oropharyngeal leak pressure but no changes in cuff position in different head and neck positions for the flexible and standard laryngeal mask airways. Oropharyngeal leak pressure may be improved by head and neck flexion and by avoiding extension.
منابع مشابه
Influence of Head and Neck Position on Oropharyngeal Leak Pressure and Cuff Position with the ProSeal Laryngeal Mask Airway and the I-Gel: A Randomized Clinical Trial
Background. This study was designed to assess and compare the effect of head and neck position on the oropharyngeal leak pressures and cuff position (employing fibreoptic view of the glottis) and ventilation scores between ProSeal LMA and the I-gel. Material and Methods. After induction of anesthesia, the supraglottic device was inserted and ventilation confirmed. The position of the head was r...
متن کاملLimitation of Laryngeal Mask Airway Usage in Open-Neck Procedure
I read the manuscript entitled “Case Report of An Open Neck Procedure Complication Associated with Laryngeal Mask Airway Use” by Subramaniam T et al. This is a valuable manuscript describing iatrogenic complications during level-2 cervical lymph node biopsy, in which the airway is managed with laryngeal mask airway (LMA). During the procedure, the surgeon realized that the mass was actually the...
متن کاملInfluence of cuff volume on oropharyngeal leak pressure and fibreoptic position with the laryngeal mask airway.
We studied the size 4 laryngeal mask airway (LMA) to test the hypothesis that oropharyngeal leak pressure and fibreoptic position improves with increasing cuff volume. After LMA insertion, 50 anaesthetized adult patients had the cuff inflated in 5-ml increments to 40 ml. Oropharyngeal leak pressure was optimal at 15 ml and decreased at higher volumes. The fibreoptic position was optimal at 0-20...
متن کاملCase Report of an open Neck Procedure Complication Associated with Laryngeal Mask Airway Use
Introduction: The laryngeal mask airway (LMA) is a safe method to establish airway control during general anaesthesia. In otolaryngology surgery, the use of a LMA is well established in ear surgery; however, the use of a LMA during open neck procedures remains controversial. We report a case in which the pharyngeal distortion by the LMA cuff resulted in an iatrogenic complication. Case Report...
متن کاملA randomized prospective controlled trial comparing the laryngeal tube suction disposable and the supreme laryngeal mask airway: the influence of head and neck position on oropharyngeal seal pressure
BACKGROUND The Laryngeal Tube Suction Disposable (LTS-D) and the Supreme Laryngeal Mask Airway (SLMA) are second generation supraglottic airway devices (SADs) with an added channel to allow gastric drainage. We studied the efficacy of these devices when using pressure controlled mechanical ventilation during general anesthesia for short and medium duration surgical procedures and compared the o...