Extending Three-Dimensional Weighted Cone Beam Filtered Backprojection (CB-FBP) Algorithm for Image Reconstruction in Volumetric CT at Low Helical Pitches

نویسندگان

  • Xiangyang Tang
  • Jiang Hsieh
  • Roy A. Nilsen
  • Scott M. McOlash
چکیده

A three-dimensional (3D) weighted helical cone beam filtered backprojection (CB-FBP) algorithm (namely, original 3D weighted helical CB-FBP algorithm) has already been proposed to reconstruct images from the projection data acquired along a helical trajectory in angular ranges up to [0, 2 π]. However, an overscan is usually employed in the clinic to reconstruct tomographic images with superior noise characteristics at the most challenging anatomic structures, such as head and spine, extremity imaging, and CT angiography as well. To obtain the most achievable noise characteristics or dose efficiency in a helical overscan, we extended the 3D weighted helical CB-FBP algorithm to handle helical pitches that are smaller than 1: 1 (namely extended 3D weighted helical CB-FBP algorithm). By decomposing a helical over scan with an angular range of [0, 2π + Δβ] into a union of full scans corresponding to an angular range of [0, 2π], the extended 3D weighted function is a summation of all 3D weighting functions corresponding to each full scan. An experimental evaluation shows that the extended 3D weighted helical CB-FBP algorithm can improve noise characteristics or dose efficiency of the 3D weighted helical CB-FBP algorithm at a helical pitch smaller than 1: 1, while its reconstruction accuracy and computational efficiency are maintained. It is believed that, such an efficient CB reconstruction algorithm that can provide superior noise characteristics or dose efficiency at low helical pitches may find its extensive applications in CT medical imaging.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Exact and approximate algorithms for helical cone-beam CT.

This paper concerns image reconstruction for helical x-ray transmission tomography (CT) with multi-row detectors. We introduce two approximate cone-beam (CB) filtered-backprojection (FBP) algorithms of the Feldkamp type, obtained by extending to three dimensions (3D) two recently proposed exact FBP algorithms for 2D fan-beam reconstruction. The new algorithms are similar to the standard Feldkam...

متن کامل

PI-line-based image reconstruction in helical cone-beam computed tomography with a variable pitch.

Current applications of helical cone-beam computed tomography (CT) involve primarily a constant pitch where the translating speed of the table and the rotation speed of the source-detector remain constant. However, situations do exist where it may be more desirable to use a helical scan with a variable translating speed of the table, leading a variable pitch. One of such applications could aris...

متن کامل

Katsevich-Type Algorithms for Variable Radius Spiral Cone-Beam CT

To solve the long object problem, an exact and efficient algorithm has been recently developed by Katsevich. While the Katsevich algorithm only works with standard helical cone-beam scanning, there is an important need for nonstandard spiral cone-beam scanning. Specifically, we need a scanning spiral of variable radius for our newly proposed electron-beam CT/micro-CT prototype. In this paper, f...

متن کامل

Iterative Filtered Backprojection Methods for Helical Cone-Beam CT

State-of-the-art reconstruction algorithms for medical helical cone-beam Computed Tomography (CT) are of type non-exact Filtered Backprojection (FBP). They are attractive because of their simplicity and low computational cost, but they produce sub-optimal images with respect to artifacts, resolution, and noise. This thesis deals with possibilities to improve the image quality by means of iterat...

متن کامل

Filtered-backprojection reconstruction for a cone-beam computed tomography scanner with independent source and detector rotations.

PURPOSE A new cone-beam CT scanner for image-guided radiotherapy (IGRT) can independently rotate the source and the detector along circular trajectories. Existing reconstruction algorithms are not suitable for this scanning geometry. The authors propose and evaluate a three-dimensional (3D) filtered-backprojection reconstruction for this situation. METHODS The source and the detector trajecto...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International Journal of Biomedical Imaging

دوره 2006  شماره 

صفحات  -

تاریخ انتشار 2006