The Argonne Wakefield Accelerator High Current Photocathode Gun and Drive Linac

نویسندگان

  • P. Schoessow
  • E. Chojnacki
  • G. Cox
  • W. Gai
  • C. Ho
  • R. Konecny
  • J. Power
  • M. Rosing
  • N. Barov
چکیده

The Argonne Wake®eld Accelerator (AWA) is a new facility for advanced accelerator research. A major component of the AWA is its drive linac, consisting of a unique high current short pulse L-Band photocathode based gun and special standing wave preaccelerator designed to produce 100 nC, 30 ps electron bunches at 20 MeV. Commissioning on the drive linac is now underway. We report on our initial operating experience with this novel machine, including bunch length and emittance measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Photoelectron beams from the UCLA rf gun

A high brightness, low emittance photocathode rf gun is starting operation at UCLA as an injector to a 20 MeV linac. This linac will initially be used to drive FELs, plasma wakefield accelerators, and to test plasma lenses. The gun is a 1 89 cell ~r-mode standing wave structure running at 2.856 GHz, and has a copper photocathode. In the initial commissioning of the gun, photoelectron beams of u...

متن کامل

The Argonne Wakefield Accelerator: Upgrade Scenarios and Future Experiments

The Argonne Wakefield Accelerator is presently operational and nearing completion of its initial dielectric structureand plasma-based experimental program. In this paper a number of possible future improvements and directions for the AWA are discussed including photocathode source upgrades, laser pulse and beam shaping options, multiple drive bunch generation, and novel wakefield device measure...

متن کامل

Observation of transverse space charge effects in a mutli-beamlet electron bunch produced in a photo-emission electron source

A "multiple beamlet" experiment aimed at investigating the transverse space charge effect was recently conducted at the Argonne Wakefield Accelerator. The experiment generated a symmetric pattern of 5 beamlets on the photocathode of the RF gun with the drive laser. We explored the evolution of the thereby produced 5 MeV, space-charge dominated electron beamlets in the 2m drift following the RF ...

متن کامل

High-gradient Generation in Dielectric-loaded Wakefield Structures*

Dielectric loaded wakefield structures have potential to be used as high gradient accelerator components. Using the high current drive beam at the Argonne Wakefield Accelerator Facility, we employed cylindrical dielectric loaded wakefield structures to generate accelerating fields of up to 86 MV/m, at 10 GHz. Short electron bunches of up to 86 nC are used to drive these fields, either as single...

متن کامل

Laser System for a Subpicosecond Electron Linac

At the Argonne Chemistry Division efforts are underway to develop a sub-picosecond electron beam pulse radiolysis facility for chemical studies. The target output of the accelerator is to generate electron pulses that can be adjusted from 3nC in .6ps to 100nC in 45ps. In conjunction with development of the accelerator a stateof-the-art ultrafast laser system is under construction that will driv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1995