Relationship between F-FDG PET SUV with Partial Volume Correction and Histology in Gastric and Gastro-Oesophageal Cancer

نویسندگان

  • Francesca Gallivanone
  • Carla Canevari
  • Paola Mapelli
  • Maria Picchio
  • Luigi Gianolli
  • Maria Carla Gilardi
  • Isabella Castiglioni
چکیده

In vivo molecular imaging techniques is increasingly used in the management of oncological patients, allowing different aspects of oncological pathologies to be assessed (e.g. metabolism, hypoxia) non invasively. The possibility to extract indexes of disease from in vivo biomedical images and to associate them with their biological drivers opens new prospective on the role of in vivo molecular imaging and expedites the translation of novel biomarkers from the bench to the clinical environment. In this work we investigate the relationship between F-FDG uptake measured by BodyWeight Standardized Uptake Value (SUVBW) as index of cell glucose metabolism, and histological indices for gastric and gastro-oesophageal cancer. For this purpose, Partial Volume Effect Correction (PVC) has been properly compensated prior to the measurement of the PET index (PVC-SUVBW). The correlation of F-FDG PVC-SUVBW with histology data was evaluated by bivariate and multivariate statistical analysis. Although obtained in a limited number of patients, our results suggest that correlations can be found when PVC is applied to SUVBW and that F-FDG PET can provide information on biological characteristics of gastric and gastro-oesophageal cancer lesions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

18F-FDG PET/CT of advanced gastric carcinoma and association of HER2 expression with standardized uptake value

Objective(s): Expression of HER2 in gastric carcinoma has direct prognostic and therapeutic implications in patient management. The aim of this study is to determine whether a relationship exists between standardized uptake value (SUV) and expression of HER2 in advanced gastric carcinoma. Methods: We analyzed the 18F-FDG PET/CT results of 109 patients that underwent gastrectomy for advanced gas...

متن کامل

Both F-18 FDG-avidity and Malignant Shape of Cervical Lymph Nodes on PET/CT after Total Thyroidectomy Predict Resistance to High-dose I-131 Therapy in Patients with Papillary Thyroid Cancer

Objective: Resistance of metastatic lymph nodes (LNs) to high dose I-131 therapy is associated with high morbidity in patients with differentiated thyroid cancer. We evaluated the role of F-18 FDG PET/CT in the prediction of resistance to high dose I-131 therapy in patients with papillary thyroid cancer. Methods: The subjects were 307 patients who underwent total or near total thyroidectomy fol...

متن کامل

Comparative assessment of methods for estimating tumor volume and standardized uptake value in (18)F-FDG PET.

UNLABELLED In (18)F-FDG PET, tumors are often characterized by their metabolically active volume and standardized uptake value (SUV). However, many approaches have been proposed to estimate tumor volume and SUV from (18)F-FDG PET images, none of them being widely agreed upon. We assessed the accuracy and robustness of 5 methods for tumor volume estimates and of 10 methods for SUV estimates in a...

متن کامل

Comparison of methods for magnetic resonance-guided [18-F]fluorodeoxyglucose positron emission tomography in human carotid arteries: reproducibility, partial volume correction, and correlation between methods.

BACKGROUND AND PURPOSE Inflammation is a major risk factor for atherosclerotic plaque rupture and clinical events. Previous studies have shown that plaque [(18)F]fluorodeoxyglucose (FDG) uptake correlates with macrophage content. In this study we examined the reproducibility of 3 methods of quantifying plaque FDG uptake in the carotid arteries using positron emission tomography (PET). The corre...

متن کامل

The influence of using different reconstruction algorithms on sensitivity of quantitative 18F-FDG-PET volumetric measures to background activity variation

Introduction: This study aims to investigate the influence of background activity variation on image quantification in differently reconstructed PET/CT images. Methods: Measurements were performed on a Discovery-690 PET/CT scanner using a custom-built NEMA-like phantom. A background activity level of 5.3 and 2.6 kBq/ml 18F-FDG were applied. Ima...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013