Repositioning a displaced tracheostomy tube with an Aintree intubation catheter mounted on a fibre-optic bronchoscope.

نویسندگان

  • R Rajendram
  • N McGuire
چکیده

Although tracheostomy tube displacement is uncommon, the management is often difficult and the associated mortality is high. It is important to ensure that the airway is secure and then either replace or reposition the tracheostomy tube. This case report describes the use of an Aintree intubation catheter (C-CAE-19.0-56-AIC, William Cook Europe, Denmark) mounted on an intubating fibre-optic bronchoscope (11302BD1, Karl Storz Endoskope, Germany) to reposition a partially displaced tracheostomy tube.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of the Aintree Intubation Catheter with the Laryngeal Mask Airway and a Fiberoptic Bronchoscope in a Patient with an Unexpected Difficult Airway

Purpose: To present a case where the Aintree intubation catheter was used in conjunction with the Laryngeal Mask Airway (LMA) and a fiberoptic bronchoscope (FOB) in a patient with an unexpected difficult airway. Clinical Features: A 38 year old 90 kg man scheduled for nasal endoscopy with ethmoidectomy under general anesthesia was found to be unexpectedly difficult to intubate using a both a MA...

متن کامل

Novel use of an exchange catheter to facilitate intubation with an Aintree catheter in a tall patient with a predicted difficult airway: a case report

INTRODUCTION The Aintree intubating catheter (Cook® Medical Inc., Bloomington, IN, USA) has been shown to successfully facilitate difficult intubations when other methods have failed. The Aintree intubating catheter (Cook® Medical Inc., Bloomington, IN, USA) has a fixed length of 56 cm, and it has been suggested in the literature that it may be too short for safe use in patients who are tall. ...

متن کامل

Usefulness of a Cook® airway exchange catheter in laryngeal mask airway-guided fiberoptic intubation in a neonate with Pierre Robin syndrome -A case report-

The case of a 33-day-old boy with Pierre Robin syndrome using a Cook® airway exchange catheter in laryngeal mask airway-guided fiberoptic intubation is presented. After induction with sevoflurane, classical reusable laryngeal mask airway (LMA) #1 was inserted and ultrathin fiberoptic bronchoscope (FOB) was passed through. A Cook® airway exchange catheter (1.6 mm ID, 2.7 mm OD) was passed throug...

متن کامل

Fluoroscope-aided retrograde placement of guide wire for tracheal intubation in patients with limited mouth opening.

Passing a retrograde catheter/wire into the pharynx through a cricothyroid puncture can facilitate tracheal intubation in difficult situations where either a flexible fibre-optic bronchoscope or an expert user of such a device is not available. Some mouth opening is essential for the oral and/or nasal retrieval of the catheter/wire from the pharynx. Two patients with temporo-mandibular joint (T...

متن کامل

Flexible Fibre-Optic Bronchoscopy in the Intensive- Care Unit

Flexible fibre-optic bronchoscopy and bronchoalveolar lavage have become important diagnostic tools for the evaluation and often for the treatment of infants and children with serious lung and airway problems causing respiratory insufficiency or failure. These patients are cared for in the paediatric or neonatal intensive-care units, and they usually require endotracheal intubation (or tracheos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 97 4  شماره 

صفحات  -

تاریخ انتشار 2006