Efficacy of continuous glucose monitoring system to detect unrecognized hypoglycemia in children and adolescents with type 1 diabetes.
نویسندگان
چکیده
This retrospective study assessed 17 DM1 pediatric patients (15.76 +/- 4.5 years) submitted to 72 h continuous glucose monitoring system (CGMS) (Medtronic, CA). The aim of this study was to evaluate the accuracy of CGMS in children and adolescents with type 1 diabetes mellitus (DM1) and the efficacy of this method to detect unrecognized hypoglycemia in this population. It were analyzed capillary glycemia (CG) and CGMS sensors value; glycemic excursions; postprandial hyperglycemia; unrecognized hypoglycemia; complications and therapeutic management after CGMS. A1c levels were measured at the start and after 3 months of the study. Correlation coefficient during hypo, hyper, and normoglycemia and sensitivity/specificity was determined. The mean CG values were 213.8 +/- 63.4 mg/dl vs. 209.7 +/- 52.5 mg/dl by sensor, with statistical significance by Pearson's correlation (p < 0.001). There was no difference between CGMS and CG value in order to detect glycemic excursions (p = 0.32). The postprandial hyperglycemia and unrecognized hypoglycemia was detected in 66.7% and 56.2% of this patients, respectively. The correlation coefficient during hypoglycemia presented no statistical significance by Pearson's correlation (p = 0.29) vs. during hyperglycemia (p = 0.001). The CGMS sensor presented low sensitivity (63.3%) to detect hypoglycemia. This data showed important decreased level of A1c in this population 3 months after CGMS with statistical significance (p = 0.03). The CGMS showed to be a very safe method, well tolerated, with high accuracy in glycemic values and low complications rate. This results suggest that CGMS is a good method to identify postprandial hyperglycemia, to improve metabolic changes in therapeutics with significant impact in A1c of diabetic pediatric patients. This data confirmed the low sensitivity of CGMS to detect unrecognized hypoglycemia in pediatric DM1 patients.
منابع مشابه
Accuracy of the GlucoWatch G2 Biographer and the continuous glucose monitoring system during hypoglycemia: experience of the Diabetes Research in Children Network.
OBJECTIVE The goal of this study was to assess the accuracy of the GlucoWatch G2 Biographer (GW2B) and the continuous glucose monitoring system (CGMS) during hypoglycemia in children and adolescents with type 1 diabetes. RESEARCH DESIGN AND METHODS During a 24-h clinical research center stay, 91 children and adolescents with type 1 diabetes (aged 3.5-17.7 years) wore one or two CGMSs, and 89 ...
متن کاملBlunted Counterregulatory Hormone Responses to Hypoglycemia in Young Children and Adolescents With Well-Controlled Type 1 Diabetes
OBJECTIVE Hypoglycemia in young children with type 1 diabetes is an acute complication of intensive insulin therapy and is commonly observed in the absence of signs or symptoms. The effect of intensive treatment and patient age on sympathoadrenal responses has not been established in youth with type 1 diabetes because of difficulties in testing procedures. RESEARCH DESIGN AND METHODS We devel...
متن کامل[Accuracy, utility and complications of continuous glucose monitoring system (CGMS) in pediatric patients with type 1 diabetes].
OBJECTIVE To evaluate the accuracy, utility and complications of continuous glucose monitoring system in children and adolescents with type 1 diabetes. METHODS This retrospective study assessed 16 type 1 diabetic patients (16.12+/-4.41 years) submitted to continuous glucose monitoring system (Medtronic; Northridge, CA) for 72 hours. The following parameters were analyzed: mean capillary gluco...
متن کاملProfessional continuous glucose monitoring in subjects with type 1 diabetes: retrospective hypoglycemia detection.
BACKGROUND An important task in diabetes management is detection of hypoglycemia. Professional continuous glucose monitoring (CGM), which produces a glucose reading every 5 min, is a powerful tool for retrospective identification of unrecognized hypoglycemia. Unfortunately, CGM devices tend to be inaccurate, especially in the hypoglycemic range, which limits their applicability for hypoglycemia...
متن کاملContinuous glucose monitoring and the reality of metabolic control in preschool children with type 1 diabetes.
OBJECTIVE To determine using the MiniMed continuous glucose monitoring system (CGMS) 1) whether twice-daily insulin injection therapy achieves adequate control in preschool children with type 1 diabetes and 2) whether the CGMS is more informative than self-monitoring of blood glucose (SMBG) regarding glucose control and well tolerated by preschool children and their families. RESEARCH DESIGN ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Arquivos brasileiros de endocrinologia e metabologia
دوره 49 4 شماره
صفحات -
تاریخ انتشار 2005