The evaluation of digital panoramic radiographs taken for implant dentistry in the daily practice.

نویسنده

  • Jun-Beom Park
چکیده

OBJECTIVES This study was conducted 1/ to find out the effects of anatomical sites and implant types on the magnification and 2/ to evaluate the inter-observer variability on the evaluation using the digital panoramas taken at daily practices. STUDY DESIGN Panoramic radiographs from 156 patients treated with implants were evaluated by three observers. The length was measured on the lateral aspect of the implant in 1:1 mode using image measurement program and the percent magnification was calculated. The inter-observer correlation coefficient was measured to express inter-observer variability using reliability analysis-scale. RESULTS The average magnification factor in the panoramic radiograph was 126.8 % in the vertical plane. Location within the anatomic arch showed different magnification by a minimum of 119.4 to a maximum of 130.8 %. The measurements among three examiners were well correlated showing correlation coefficient of 0.81. The differences between one side from the contralateral side was evaluated and it was shown that the differences were observed only seen maxillary anterior and upper premolar regions. Additionally, the external non-submerged group had the highest magnification value. CONCLUSIONS Digital panoramic radiographs showed sufficient accuracy and good inter-examiner agreement. The radiographic magnification of implant length was influenced by anatomical sites and implant types.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Common Positioning Errors in Digital Panoramic Radiographies Taken In Mashhad Dental School

Introduction: The present study was aimed at evaluating common positioning errors on panoramic radiographs taken in the Radiology Department of Mashhad Dental School. Materials and methods: The study sample included 1,990 digital panoramic radiographs taken in the Radiology Department of Mashhad Dental School by a Planmeca Promax (Planmeca Oy, Helsinki, Finland), during a 2-year period (2010–20...

متن کامل

Evaluation of Panoramic Radiography Accuracy in Estimating the Crestal Width of Dental Implant in Different Jaw Regions

Introduction: The aim of this study was to determine the accuracy of digital panoramic radiography in estimating the crestal width of implant fixtures after surgery. Materials and Methods:We selected 241 digital panoramic images after implant insertion which had documented information of their actual size. The crestal width was measured on radiographs. We compared two measuring methods in diff...

متن کامل

Common Errors in Digital Panoramic Radiographs Taken in Rasht Dental School

Introduction: The use of panoramic radiography has shown a remarkable expansion over the past 20 years. Accurate positioning and preparation of patients is needed to avoid image distortion. The aim of this study was to evaluate the common errors on panoramic radiographs taken in the radiology department of Rasht dental school. Materials and Methods: The study sample included 390 digital panoram...

متن کامل

In vitro Evaluation of the Relationship between Gray Scales in Digital Intraoral Radiographs and Hounsfield Units in CT Scans

Background: Jaw bone quality plays an essential role in treatment planning and prognosis of dental implants. Regarding several available methods for bone density measurements, they are not routinely used before implant surgery due to hard accessibility.Objective: An in vitro investigation of correlation between average gray scale in direct digital radiographs and Hounsfield units in CT-Scan pro...

متن کامل

Evaluation of Image Magnification in Digital Panoramic Radiography

Introdouction: The aim of the present study was to investigate image magnification in digital panoramic radiography and assess the effect of anatomical sites on the magnification in both males and females. Materials and methods: In this retrospective study, digital panoramic radiographs of 48 patients with 202 implants were investigated. Implant diameter and length were measured on pan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medicina oral, patologia oral y cirugia bucal

دوره 15 4  شماره 

صفحات  -

تاریخ انتشار 2010