Relationship of beam angulation and radiation exposure in the cardiac catheterization laboratory.

نویسندگان

  • Shikhar Agarwal
  • Akhil Parashar
  • Navkaranbir Singh Bajaj
  • Imran Khan
  • Imran Ahmad
  • Fredrick A Heupler
  • Matthew Bunte
  • Dhruv K Modi
  • E Murat Tuzcu
  • Samir R Kapadia
چکیده

OBJECTIVES The aim of this study was to analyze the relationship between beam angulation and air kerma in a modern cardiac catheterization laboratory. BACKGROUND Recent reports have identified the merits of reducing radiation scatter, an important determinant of radiation dose in the catheterization laboratory. Radiation scatter is poorly characterized in the context of catheterization laboratories using modern digital equipment. Understanding the principles of dosimetry may reduce the radiation exposure to patients, providers, and medical staff. METHODS Prospectively captured radiation data were extracted from a database of 1,975 diagnostic catheterizations (DCs) and 755 percutaneous coronary interventions (PCIs), which included 138,342 fluoroscopic and 35,440 acquisition (cine) sequences. Fluoroscopy and acquisition modes were categorized into tertiles based on the total air kerma measured at a standard reference point. Radiation maps were modeled according to the relative proportion of exposure in each projection. RESULTS Median air kerma during DCs and PCIs was 677 and 2,188 mGy, respectively. Fluoroscopy contributed to 66.3% of total dose during PCIs compared with 39.7% during DCs (p < 0.001). Fluoroscopy was more sensitive to changes in angulation with a rapid increase in total air kerma on small increases in beam angulation. Complex spatial maps were created to study the impact of angulation and other covariates on total air kerma. Besides beam angulation, body surface area was the strongest predictor of the total air kerma. CONCLUSIONS This study uniquely describes radiation dosimetry using contemporary equipment in a real-world setting. Extreme angulations were associated with high air kerma values. Fluoroscopy compared with acquisition was more sensitive to changes in angulation, with relatively larger increases in total air kerma with small increases in steepness of the angulation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Radiation Exposure Pattern and Radiation Absorbed Dose Resulting from Occupational Exposure of Anesthesiologists to Ionizing Radiation

Introduction: Little information is available concerning the radiation exposure of anesthesiologists, and no such data have previously been collected in Iran. This prospective study was performed to determine the amount of radiation exposure of anesthesiologists for the purpose of assessing whether or not dangerous levels of radiation exposures were being reached, and to identify factors that c...

متن کامل

Radiation Exposure to the Pediatric Patient During Cardiac Catheterization and Angiocardiography Emphasis on the Thyroid Gland ERIC

Thermoluminescent dosimetry was used to measure the radiation exposure to the skin, thyroid and gonads in 50 consecutive pediatric patients undergoing cardiac catheterization and angiocardiography using cine photofluorography. Average exposures were 17.1 R to the skin, 2.3 R to the thyroid and 0.1 R to the gonads. Fluoroscopy accounted for approximately 80% of the skin and thyroid exposure and ...

متن کامل

Radiation exposure to the pediatric patient during cardiac catheterization and angiocardiography. Emphasis on the thyroid gland.

Thermoluminescent dosimetry was used to measure the radiation exposure to the skin, thyroid and gonads in 50 consecutive pediatric patients undergoing cardiac catheterization and angiocardiography using cine photofluorography. Average exposures were 17.1 R to the skin, 2.3 R to the thyroid and 0.1 R to the gonads. Fluoroscopy accounted for approximately 80% of the skin and thyroid exposure and ...

متن کامل

Induction of cancer stem-like cells in A549 cells after exposure to carbon ions and X-rays

Background: Cancer stem-like cells (CSCs) play a crucial role in the initiation, progression, and recurrence of cancer. Evidence indicates that the high linear energy transfer (LET) carbon ion beam is more effective against CSCs than the conventional X-ray beam. Carbon ion radiotherapy is considered as a promising cancer strategy, however, information about whether, or not, new CSCs are induced...

متن کامل

Relationship between Neutrophil-to-lymphocyte Ratio and the Severity of Coronary Artery Disease in Patients Undergoing Cardiac Catheterization

Introduction: Neutrophil-to-lymphocyte ratio (NLR) is considered as an independent predictor of long-term prognosis in the individual patients with coronary artery disease (CAD). This study sought to assess the relationship between NLR and CAD severity in Iranian patients undergoing cardiac catheterization.Material and Methods: This prospective study was conducted on 500 patients with acute cor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JACC. Cardiovascular interventions

دوره 7 5  شماره 

صفحات  -

تاریخ انتشار 2014