Triphenylene based copper ensemble for the detection of cyanide ions.

نویسندگان

  • Vandana Bhalla
  • Hardev Singh
  • Manoj Kumar
چکیده

The binding behavior of triphenylene based copper ensemble prepared in situ has been investigated toward various anions (F(-), Cl(-), Br(-), I(-), CH(3)COO(-), H(2)PO(4)(-), NO(3)(-), OH(-), ClO(4)(-), CN(-), CO(3)(-) and SO(4)(-)) by UV-vis and fluorescence spectroscopy. Among various anions tested, 1-Cu(2+) ensemble shows selective and sensitive response towards cyanide ions and responds to CN(-) ions even in the presence of bovine serum albumin and in blood serum milieu. Further, as practical application of compound 1, we utilized the TLC strips coated with THF solution of 1 for the solid state detection of copper and cyanide ions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fabrication of new carbon paste electrodes based on gold nano-particles self-assembled to mercapto compounds as suitable ionophores for potentiometric determination of Copper ions

In the present study, we investigate the potentiometric behavior of Cu2+ carbon paste electrodes based on two mercapto compounds 2-Ethylmino-5-Mercapto-1,3,4-Thiadiazole (EAMT) and 2-Acetylamino-5-mercapto-1,3,4-thiadiazole (AAMT) self-assembled on gold nano-paricle (GNP) as ionophore. Then, the results obtained from the modified electrodes are compared. The self-assembled ionophores exhibit a ...

متن کامل

A new thiacalix[4]arene-fluorescein based probe for detection of CN(-) and Cu(2+) ions and construction of a sequential logic circuit.

A new thiacalix[4]arene-fluorescein based fluorescent probe was synthesized, which shows a turn-on fluorescence response in the presence of CN(-) ions attributed to the nucleophilic addition of cyanide ions and the resulting cyanide adduct was used for the selective detection of copper ions. Furthermore, based on the fluorescence response a two input, one output, sequential logic circuit was co...

متن کامل

Ion-Selective Carbon Paste Electrode Based on 2-Amino-N-benzthioazolyl Benzamide (ABTB) for Determination of Copper (II) by Potentiometric Method

2-Amino-N-benzthioazolyl benzamide (ABTB) was synthesized, characterized and used for thefabrication of a potentiometric sensor for Cu2+ metal ions. The electrode exhibits linear response to Cu(II) over a wide concentration range (4.79×10 -8 – 1.85×10 -1 M) with Nernstian slope of 30 ± 1.5 mVper decade. The electrode can be used in the pH range from 2 to 9. It has a fast response time of about1...

متن کامل

Turn-on fluorescent cyanide sensor based on copper ion-modified CdTe quantum dots.

A new fluorescent sensor for the sensitive and selective detection of cyanide (CN(-)) in aqueous media was developed herein. The sensing approach is based on CN(-)-modulated quenching behavior of Cu(2+) toward the photoluminescence (PL) of CdTe quantum dots (QDs). In the presence of CN(-), the PL of QDs that have been quenched by Cu(2+) was found to be efficiently recovered, which then allows t...

متن کامل

بررسی کارایی فرایند تصفیه الکتروشیمیایی در حذف سیانید از فاضلاب صنعتی

Background and Objectives: Cyanide is a highly toxic compound which is Normally found in numerous industries, such as electroplating wastewater. Release of this compounds in to the Enviroment has a lot health hazards.The Purpose of this study is to Determine the efficiency of electrochemical oxidation method for Cyanide removal from industrial wastewaters Materials and Methods: This study con...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Dalton transactions

دوره 41 37  شماره 

صفحات  -

تاریخ انتشار 2012